Why the study?
Because between-subject and within-subject flow variabilities are large, neither one-shot measurements nor cohort mean values accurately reflect an individual patient's carotid flow regime in computational fluid dynamics models.
Answers are grounded in this paper and cite their sources.
Oscillatory shear index (OSI) is highly sensitive to physiological flow fluctuations between rest and exercise, suggesting it may not be a reliable biomarker in vascular computational fluid dynamics studies.
Computational fluid dynamics models are increasingly proposed for assisting the diagnosis and management of vascular diseases. Ideally, patient-specific flow measurements are used to impose flow boundary conditions. When patient-specific flow measurements are unavailable, mean values of flow measurements across small cohorts are used as normative values. In reality, both the between-subjects and within-subject flow variabilities are large. Consequently, neither one-shot flow measurements nor mean values across a cohort are truly indicative of the flow regime in a given person. We develop models for both the between-subjects and within-subject variability of internal carotid flow. A log-linear mixed effects model is combined with a Gaussian process to model the between-subjects flow variability, while a lumped parameter model of cerebral autoregulation is used to model the within-subject flow variability in response to heart rate and blood pressure changes. The model parameters are identified from carotid ultrasound measurements in a cohort of 103 elderly volunteers. We use the models to study intracranial aneurysm flow in 54 subjects under rest and exercise and conclude that OSI, a common wall shear-stress derived quantity in vascular CFD studies, may be too sensitive to flow fluctuations to be a reliable biomarker.
No takes yet. Share an insight, caveat, or question.
Lassila et al. (2019) studied Healthy elderly (free of cardiovascular disease) (n=103). Simulated physical exercise (increased heart rate and blood pressure) vs. Rest was evaluated on Oscillatory shear index (OSI) (124.0% increase).
Synapse has enriched 10 related papers. Consider them for comparative context: