This is the authors' abstract. We don't add key points for this paper.
The effect of nanosized gold particles on the adsorption-sensitive properties of SnO 2 –Au sensors under the detection of acetone vapors has been studied. Different techniques for the preparation of SnO 2 –Au nanocomposites with an average Au particle size of 2 nm were applied. It has been found that a fivefold increase in the sensor response to acetone vapors and threshold sensitivity ( C lim ) of 0.1 ppm are achieved by adding gold to tin dioxide in the colloidal form during synthesis. While adding gold in ion form (Au (III)) leads to a growth of the sensor response to acetone vapors by 2.7 times and defines C lim of 0.2 ppm. The slope of the calibration curves of the SnO 2 –Au sensors allows registering acetone vapors at concentrations ranging from C lim to 5 ppm. This concentration range can be used for express diagnostics in diabetes. The enhanced sensitivity of SnO 2 –Au sensors to acetone vapors can be explained by an increase in the adsorption-catalytic activity of tin ions as a result of the modifying effect of sulfate groups and the envolving of highly dispersed gold in the adsorption – catalytic process of oxidation of acetone molecules.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Ovodok et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: