An ATP-dependent co-operative Ca2+ binding model accurately reproduces cardiac Ca2+ transients and demonstrates significant perturbation of peak-systolic Ca2+ by spectroscopic indicators.
Answers are grounded in this paper and cite their sources.
Indicator buffering may artifactually blunt peak [Ca2+]i; extends cooperative models but leaves experimental corrections open.
The measurement of cardiac Ca(2+) transients using spectroscopic Ca(2+) indicators is significantly affected by the buffering properties of the indicators. The aim of the present study was to construct a model of cardiac Ca(2+) buffering that satisfied the kinetic constraints imposed by the maximum attainable rates of cardiac contraction and relaxation on the Ca(2+) dissociation rate constants and which would account for the observed effects of (19)F-NMR indicators on the cardiac Ca(2+) transient in the Langendorff-perfused ferret heart. It is generally assumed that the Ca(2+) dependency of myofibril activation in cardiac myocytes is mediated by a single Ca(2+)-binding site on troponin C. A model based on 1:1 Ca(2+) binding to the myofilaments, however, was unable to reproduce our experimental data, but a model in which we assumed ATP-dependent co-operative Ca(2+) binding to the myofilaments was able to reproduce these data. This model was used to calculate the concentration and dissociation constant of the ATP-independent myofilament Ca(2+) binding, giving 58 and 2.0 microM respectively. In addition to reproducing our experimental data on the concentration of free Ca(2+) ions in the cytoplasm ([Ca(2+)](i)), the resulting Ca(2+) and ATP affinities given by fitting of the model also provided good predictions of the Ca(2+) dependence of the myofibrillar ATPase activity measured under in vitro conditions. Solutions to the model also indicate that the Ca(2+) mobilized during each beat remains unchanged in the presence of the additional buffering load from Ca(2+) indicators. The new model was used to estimate the extent of perturbation of the Ca(2+) transient caused by different concentrations of indicators. As little as 10 microM of a Ca(2+) indicator with a dissociation constant of 200 nM will cause a 20% reduction in peak-systolic [Ca(2+)](i) and 30 microM will cause approx. 50% reduction in the peak-systolic [Ca(2+)](i) in a heart paced at 1.0 Hz.
No takes yet. Share an insight, caveat, or question.
Smith et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: