Answers are grounded in this paper and cite their sources.
Demonstrates effective dead-time compensation in PM synchronous motor drives, suggesting improved performance.
In this paper, an on-line dead-time compensation method based on a time delay control approach is presented. The disturbance voltages caused by the dead time are estimated in an on-line manner by the time delay control without any additional circuits and off-line experimental measurements. The estimated disturbance voltages are fed to voltage references in order to compensate the dead-time effects. The proposed method is applied to a PM synchronous motor drive system and implemented by using software of a digital signal processor (DSP) TMS320C31. Experiments are carried out for this system and the results well demonstrate the effectiveness of the proposed method.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2002) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: