Answers are grounded in this paper and cite their sources.
The need to achieve high performance with very high control accuracy in an electrical machine is paramount and has led to increased interest in modern motor control techniques. Modern motor techniques often require position sensors to be integrated into electrical machines. The position estimation approach offers a cost advantage within acceptable error results over the position measurement approach, making the position estimation approach more suitable. This paper deals with sensorless position control of a synchronous reluctance machine (SynRM) by applying the load torque of an electric vehicle drive train based on an extended Kalman filter (EKF). The developed observer could be an excellent replacement for the analogue position sensor. This work is done in two steps: Firstly, the EKF observer is synthesised and secondly, two types of controllers are used for velocity and currents; the PI and the super-twisting controllers. The simulation results obtained in this work confirm the accuracy and reliability of the developed observer with the super-twisting controllers.
No takes yet. Share an insight, caveat, or question.
Boukhnifer et al. (2024) studied this question.
Synapse has enriched 7 closely related papers on similar clinical questions. Consider them for comparative context: