June 3, 2026Energies0 citationsOpen Access

Suppression Method of Sub/Super-Synchronous Oscillation in Direct-Drive Wind Farms Based on a Hybrid GFL-GFM Control Configuration

View Full Paper
KWKun WangJLJiang Li

Key Points

  • This research aims to analyze the influences of grid-forming control on mitigating oscillations in direct-drive wind farms.
  • Establishes sequence impedance models for GFL and GFM control.
  • Calculates the stability margin considering various operational constraints.
  • Assesses the mitigation effects of GFM turbine placement on oscillations.
  • Identified feasible ranges of short-circuit ratios for stable operation under various conditions.
  • Demonstrated improvements in system stability via Nyquist curve analysis.
  • Validated method effectiveness through electromagnetic transient simulations in MATLAB/Simulink.

Abstract

Currently, grid-following (GFL) control is widely adopted in direct-drive wind farms. Its external impedance characteristic exhibits negative resistance and capacitive reactance, frequently inducing sub/super-synchronous oscillations in the direct-drive wind farm and weak grid interactive system. The positive resistance characteristic of grid-forming (GFM) control can, to a certain extent, improve the impedance characteristic of wind farms and enhance the system stability margin. However, the influence of the proportion and deployment location of GFM control within a wind farm on the mitigation of sub/super-synchronous oscillations merits further exploration. First, this paper establishes the sequence impedance models for both GFL and GFM control, analyzes the underlying causes of system oscillations from an impedance perspective, and proposes a method for calculating the stability margin of a grid-connected direct-drive wind farm system that comprehensively accounts for the generalized short-circuit ratio, the critical short-circuit ratio of the equipment, and the steady-state operational constraints of the system. Subsequently, the mitigation effects of the connection location and capacity proportion of GFM wind turbines on sub/super-synchronous oscillations are quantitatively assessed, yielding feasible ranges of the short-circuit ratio under various operating conditions that ensure stable operation of the direct-drive wind farm. The system stability is further examined via Nyquist curve analysis. Finally, the effectiveness of the proposed method is validated by electromagnetic transient simulations in MATLAB/Simulink.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/6a1fc56bdee9eb8c0dce6cd9https://doi.org/10.3390/en19112661
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Small-Signal Stability Assessment of Heterogeneous Grid-Following Converter Power Systems Based on Grid Strength Analysis2022 · 92 citations
  2. 2Small-Signal Methods for AC Distributed Power Systems–A Review2009 · 714 citations
  3. 3PLL phase margin design and analysis for mitigating sub/super-synchronous oscillation of grid-connected inverter under weak grid2023 · 28 citations
  4. 4Achieving a 100% Renewable Grid: Operating Electric Power Systems with Extremely High Levels of Variable Renewable Energy2017 · 1,356 citations
  5. 5Grid-Forming Inverters: A Critical Asset for the Power Grid2019 · 855 citations