Key result
EEMD with modified sigmoid thresholding improves ECG denoising by ~12 dB in abnormal records.
The proposed EEMD and MSTF-based algorithm effectively reduces noise and preserves QRS complexes in ECG signals, outperforming conventional denoising methods.
May improve ECG interpretation amid noise; leaves open prospective clinical validation.
Objectives Novel noise reduction and QRS detection algorithms in Electrocardiogram (ECG) signal based on Empirical Mode Decomposition (EMD), Ensemble Empirical Mode Decomposition (EEMD) and the Modified Sigmoid Thresholding Function (MSTF) are proposed in this paper. Methods EMD and EEMD algorithms are used to decompose the noisy ECG signal into series of Intrinsic Mode Functions (IMFs). Then, these IMFs are thresholded by the MSTF for reduction of noises and preservation of QRS complexes. After that, the thresholded IMFs are used to obtain the clean ECG signal. The characteristic points P, Q, R, S and T peaks are detected using peak detection algorithm. Results The proposed methods are validated through experiments on the MIT-BIH arrhythmia database and Additive White Gaussian Noise (AWGN) is added to the clean ECG signal at different input SNR ( SNR in ). Standard performance parameters output SNR ( SNR out ), mean square error ( MSE ), root mean square error ( RMSE ), SNR improvement ( SNR imp ) and percentage root mean square difference ( PRD ) are employed for evaluation of the efficacy of the proposed methods. The results showed that the proposed methods provide significant quantitative and qualitative improvements in denoising performance, compared with existing state-of-the-art methods such as wavelet denoising, conventional EMD (EMD-Conv), conventional EEMD (EEMD-Conv, Stockwell Transform (ST) and Complete EEMD with Adaptative Noise with hybrid interval thresholding and higher order statistic to select relevant modes (CEEMDAN-HIT). Conclusions A detail quantitative analysis demonstrate that for abnormal ECG records 207 m and 214 m at input SNR of −2 dB the SNR imp value is 12.22 and 11.58 dB respectively, which indicates that the proposed algorithm can be used as an effective tool for denoising of ECG signals.
No takes yet. Share an insight, caveat, or question.
Ouahiba Mohguen (2023) studied ECG signal noise. EEMD with modified sigmoid thresholding (MSTF) vs. Wavelet denoising, conventional EMD, conventional EEMD, ST, and CEEMDAN-HIT was evaluated on SNR improvement (SNR imp). The proposed EEMD with modified sigmoid thresholding algorithm provided significant improvements in ECG denoising, achieving an SNR improvement of 12.22 dB for abnormal records at -2 dB input SNR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: