Key result
Enterovirus cross-neutralisation is uncommon, but anti-CVA20 and anti-CVA24 show activity against select echoviruses.
Why the study?
The assumption that enterovirus neutralisation is type-specific, which underpins the reliability of sero-surveillance, has been challenged by recent data.
Does cross-neutralisation occur between different enterovirus types in animal sera?
Does cross-neutralisation occur between different enterovirus types in animal sera?
Answers are grounded in this paper and cite their sources.
Cross-neutralisation among enteroviruses is generally uncommon but present in specific types, highlighting the need for further evaluation in human sero-surveillance.
Enteroviruses (EV) are worldwide circulating viruses causing a broad range of disease manifestations. Sero-surveillance, by measuring neutralising antibodies against specific EV types, can provide valuable information on viral spread and community circulation. EV neutralisation is generally regarded as type-specific, providing the foundation for the reliability of EV sero-surveillance. Recent data has challenged the assumption of type-specific neutralisation. To study the extent of cross-neutralisation, we measured neutralising antibody titres in EV type-specific polyclonal animal sera against twelve recently circulating homotypic and heterotypic clinical and prototype strains belonging to all four EV species, making use of virus neutralisation assays. We found no cross-neutralising Abs against EV-A71, CVA4, CVB2, CVB5, CVA24, and EV-D68. No cross-neutralising antibodies were found in poliovirus 1, 2 and 3 anti-sera. However, cross-neutralising antibodies were found in anti-CVA20 and anti-CVA24 animal sera against the included echovirus types, E11 and E30. Our study demonstrates that cross-neutralisation among EV is generally uncommon, though not absent. To enhance the reliability and comparability of sero-surveillance studies, cross-neutralisation between geno- and subgenotypes should be further evaluated in humans and virus neutralisation assays (VNA) should be further standardised.
No takes yet. Share an insight, caveat, or question.
Couderé et al. (2026) studied Enterovirus infection. EV type-specific polyclonal animal sera was evaluated on Cross-neutralising antibody titres. Cross-neutralisation among enteroviruses was generally uncommon, though cross-neutralising antibodies were found in anti-CVA20 and anti-CVA24 animal sera against echovirus types E11 and E30.
Synapse has enriched 10 related papers. Consider them for comparative context: