Key result
Ventricular untwisting had little influence on the propagation velocity of color M-mode Doppler echocardiograms (0.42 m/s with untwisting vs 0.43 m/s without).
Why the study?
Does ventricular untwisting affect intraventricular diastolic flow and color M-mode Doppler echocardiogram patterns?
Does ventricular untwisting affect intraventricular diastolic flow and color M-mode Doppler echocardiogram patterns?
Absolute Event Rate: 0.42% vs 0.43%
Color M-mode Doppler echocardiography can capture flow dynamics produced by ventricular expansion with little influence from ventricular untwisting, making it advantageous for assessing left ventricular diastolic function.
Suggests color M-mode propagation velocity reflects ventricular expansion independent of untwisting; leaves open its clinical utility for diastolic assessment pending human studies.
Intraventricular hemodynamics during diastole was numerically analyzed in order to investigate effects of a ventricular untwisting on flow and a pattern of a color M-mode Doppler echocardiogram. Results showed that the ventricular untwisting affected secondary flows by inducing spiral flows in the ventricular cavity especially in the apical region. On the other hand, flows in the long-axis plane were not affected. Timing of formation, size and growing manner of the annular vortex were almost the same regardless of the presence of the ventricular untwisting; the vortex firstly arose in the base region, expanded towards the apex and eventually occupied the upper half of the ventricular cavity. A pattern of a color M-mode Doppler echocardiogram, that is, a spatiotemporal map of velocity along the long axis, was topologically the same as quantitatively confirmed by comparison of propagation velocity (0.43 m/s and 0.42 m/s for the case without and with the ventricular untwisting, respectively). These results suggested that this technique can exclusively capture flow dynamics produced by ventricular expansion with little influence of the ventricular untwisting. Therefore, we concluded that this is advantageous for assessing a left ventricular diastolic function.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (2005) studied Left ventricular diastolic function. Ventricular untwisting vs. Without ventricular untwisting was evaluated on Propagation velocity of color M-mode Doppler echocardiogram. Ventricular untwisting had little influence on the propagation velocity of color M-mode Doppler echocardiograms (0.42 m/s with untwisting vs 0.43 m/s without).