Key result
The NF-Heart continuous authentication system utilizing a ballistocardiogram achieved a mean balanced accuracy of 96.45% and a median equal error rate of 3.83%.
Why the study?
One-pass authentication fails to meet cybersecurity needs for increasingly remote workforces, highlighting the need for continuous authentication systems.
A novel continuous authentication system using chair-based ballistocardiogram signals achieves high accuracy for remote workforce security.
Answers are grounded in this paper and cite their sources.
Supports BCG-based authentication development; leaves open validation in cardiovascular cohorts.
The increasingly remote workforce resulting from the global coronavirus pandemic has caused unprecedented cybersecurity concerns to organizations. Considerable evidence has shown that one-pass authentication fails to meet security needs when the workforce work from home. The recent advent of continuous authentication (CA) has shown the potential to solve this predicament. In this paper, we propose NF-Heart, a physiological-based CA system utilizing a ballistocardiogram (BCG). The key insight is that the BCG measures the body's micro-movements produced by the recoil force of the body in reaction to the cardiac ejection of blood, and we can infer cardiac biometrics from BCG signals. To measure BCG, we deploy a lightweight accelerometer on an office chair, turning the common chair into a smart continuous identity "scanner". We design multiple stages of signal processing to decompose and transform the distorted BCG signals so that the effects of motion artifacts and dynamic variations are eliminated. User-specific fiducial features are then extracted from the processed BCG signals for authentication. We conduct comprehensive experiments on 105 subjects in terms of verification accuracy, security, robustness, and long-term availability. The results demonstrate that NF-Heart achieves a mean balanced accuracy of 96.45% and a median equal error rate of 3.83% for CA. The proposed signal processing pipeline is effective in addressing various practical disturbances.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2023) studied this question. NF-Heart (physiological-based continuous authentication system utilizing a ballistocardiogram) was evaluated on Verification accuracy and equal error rate for continuous authentication (median equal error rate 3.83%). The NF-Heart continuous authentication system utilizing a ballistocardiogram achieved a mean balanced accuracy of 96.45% and a median equal error rate of 3.83%.
Synapse has enriched 10 related papers. Consider them for comparative context: