Answers are grounded in this paper and cite their sources.
We conducted an electromagnetic-thermal analysis of Petri dishes filled with different medium volumes under different radio frequency exposure conditions with the aim of identifying linear and non-linear parameters that might explain contradictory results of many in vitro bioelectromagnetic experiments. We found that power loss density and temperature depend on shape, size, and orientation of the exposed sample with respect to direction of incident energy, showing that the liquid medium acts as a receiving antenna. In addition, we investigated the possibility of convection from thermodynamic principles within the liquid medium. For a 35 mm diameter Petri dish, a 2 or 4 ml medium volume is too small to support vertical convection. Conversely, horizontal convective motion is possible for H-polarization exposures at 1.8 GHz.
No takes yet. Share an insight, caveat, or question.
Paffi et al. (2015) studied this question.