Answers are grounded in this paper and cite their sources.
Chest excursion measurements are commonly used to assess the effect of disease on chest wall motion. The purpose of this study was to determine if site of tape measure placement and subject position affect chest excursion measurements. Data were collected on sixty healthy participants between the ages of 19-34. Chest girth measurements were obtained during two slow vital capacity maneuvers (VCMs) in three positions (supine, sitting, standing) and at two measurement site (xiphoid, axilla). Chest excursion differed with measurement site, but no main effects of gender or position on chest excursion were found. A significant interaction between measurement site and subject position was found. Chest excursion measurements taken in the standing position at the xiphoid site (x = 7.9 cm) were greater than those at the axillary site (x = 6.8 cm). Chest excursion measurements taken at the xiphoid site in standing (x = 7.9 cm) were greater than in supine (x= 7.2 cm). This study demonstrates that measurement site and subject position influence chest excursion values. Clinical recommendations based on these results include the use of two measurement sites for a thorough evaluation of pulmonary status, the establishment and use of a consistent measurement site and subject position for each patient, and proper documentation of these variables throughout the treatment process.
No takes yet. Share an insight, caveat, or question.
Harris et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: