Key result
Biodegradable polymer sirolimus-eluting stents resulted in a lower percentage of uncovered struts at 3 months compared to durable polymer zotarolimus-eluting stents (3.9% vs. 8.9%, p<0.001) in non-diabetic patients with acute coronary syndrome.
Why the study?
Does a biodegradable polymer sirolimus-eluting stent improve early neointimal coverage and vasodilator response compared to a durable polymer zotarolimus-eluting stent in non-diabetic patients with acute coronary syndrome?
RCT (n=44)
Single-blind
1:1
Yes
Does a biodegradable polymer sirolimus-eluting stent improve early neointimal coverage and vasodilator response compared to a durable polymer zotarolimus-eluting stent in non-diabetic patients with acute coronary syndrome?
In non-diabetic patients with ACS, biodegradable polymer sirolimus-eluting stents provided slightly better early stent strut coverage at 3 months compared with durable polymer zotarolimus-eluting stents, though neither stent was fully covered and vasodilator response was similar.
May favor biodegradable polymer stents for faster early coverage in non-diabetic ACS; extends OCT healing comparisons without clinical outcome data.
BACKGROUND: Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. METHODS AND RESULTS: Forty-four non-diabetic patients with acute coronary syndrome (ACS) and culprit lesion in the LAD were randomized to receive either biodegradable polymer sirolimus-eluting stent (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES). Neointimal strut coverage was examined using optical coherence tomography, and vasodilator response on invasive thermodilution-derived coronary flow reserve (CFR) at 3-month follow-up. The primary endpoints were percent uncovered struts and CFR. A total of 425 cross-sections (4,897 struts) were analyzed in the BP-SES group, and 425 cross-sections (5,467 struts) in the DP-ZES group. The percent uncovered struts was lower in the BP-SES group compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P<0.001), and stent level (3.9 ± 3.2% vs. 8.9 ± 6.9%, respectively, P=0.019). No significant difference was found between the 2 groups regarding CFR (3.0 ± 1.3 vs. 3.2 ± 1.0, respectively, P>0.05). CONCLUSIONS: In non-diabetic patients with ACS, BP-SES provided slightly better stent strut coverage at 3 months compared with DP-ZES, but neither stent was fully covered. No difference in vasodilator response was seen.
No takes yet. Share an insight, caveat, or question.
Karjalainen et al. (2014) conducted an RCT in Acute coronary syndrome (n=44). Biodegradable polymer sirolimus-eluting stent (BP-SES) vs. Durable polymer zotarolimus-eluting stent (DP-ZES) was evaluated on Percent uncovered struts (strut level) (p=<0.001). Biodegradable polymer sirolimus-eluting stents resulted in a lower percentage of uncovered struts at 3 months compared to durable polymer zotarolimus-eluting stents (3.9% vs. 8.9%, p<0.001) in non-diabetic patients with acute coronary syndrome.