Key result
Short-term heart rate asymmetry occurs in ~98% of healthy adults on 48-hour Holter monitoring.
Why the study?
Heart rate asymmetry reflects differing contributions of heart rate decelerations and accelerations to heart rate variability, but reference data from longer ECG recordings up to 48 hours were needed.
Cross-Sectional (n=101)
No
p-value: p=<0.0001
Heart rate asymmetry features are present in most healthy adults during 48-hour Holter monitoring, providing reference values for clinical ECG monitoring.
Provides normative HRA data in healthy adults; leaves open diagnostic utility in clinical populations.
Heart rate asymmetry (HRA) reflects different contributions of heart rate (HR) decelerations and accelerations to heart rate variability (HRV). In this study, we examined various properties of HRA, including its compensation and HRV, in 48-h electrocardiogram (ECG) recordings in healthy adults. Furthermore, we compared sex differences in parameters used to quantify HRA and HRV. Variance-based and relative HRA and HRV parameters were computed for Holter ECG recordings lasting up to 48 h in 101 healthy volunteers. The median age of the subjects was 39 years, with 47 of them being men. The prevalence of all forms of HRA was statistically different from randomness (p < 0.0001). Specifically, HR decelerations contributed >50% (C1d) to short-term HRA in 98.02% of subjects, while HR decelerations contributed <50% to long-term HRA in 89.11% of recordings and to total HRA in 88.12% of recordings. Additionally, decelerations accounted for <50% of all changing heartbeats (Porta’s index) in 74.26% of subjects, and HRA compensation was present in 88.12% of volunteers. Our findings suggest that various HRA features are present in most healthy adults. While men had more pronounced HRA expression, the prevalence of short-, long-term, and total HRA and its compensation was similar in both sexes. For HRV, values of variance-based indices were higher in men than in women, but no differences were found for relative measures. In conclusion, our study references HRA and HRV for longer ECG recordings of up to 48 h, which have become increasingly important in clinical ECG monitoring. The findings can help understand and compare the characteristics of HRA and HRV in patients with different diseases.
No takes yet. Share an insight, caveat, or question.
Sibrecht et al. (2023) conducted a cross-sectional in Healthy adults (n=101). 48-hour Holter ECG monitoring was evaluated on Prevalence of short-term heart rate asymmetry (C1d > 50%) (p=<0.0001). In 48-hour Holter ECG recordings of healthy adults, short-term heart rate asymmetry was present in 98.02% of subjects, and all forms of HRA were statistically different from randomness (p<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: