Echocardiographic monitoring during mental stress testing improved detection of ischemia compared to electrocardiography (37.5% vs 3.6% of patients), with 73.5% sensitivity and 93.3% specificity.
Observational (n=56)
Does echocardiographic monitoring improve the sensitivity of mental stress testing for detecting ischemia in patients with ischemic heart disease compared to electrocardiographic monitoring?
Echocardiography significantly improves the sensitivity of mental stress testing for detecting ischemia in coronary patients compared to standard electrocardiographic monitoring.
Absolute Event Rate: 37.5% vs 3.6%
Mental stress testing can induce ischemia in coronary patients, but often may not induce chest pain and/or electrocardiographic changes. Therefore, we tested the utility of echocardiography to increase the sensitivity of the method. For this purpose, 56 patients undertook arithmetic mental stress tests and then were subjected to coronary angiography. During the test we evaluated left ventricular function, electrocardiography results, and emotional involvement measured by STAI (State Trait Anxiety Inventory). Echocardiography was positive in 21 patients, and electrocardiogram only in 2 patients. No patient complained of chest pain. The remaining 35 patients were negative. Comparing echo data with coronary angiography, in all the cases, sensitivity was 73.5%, specificity 93.3%. Analysis of the STAI revealed that the negative test we observed could be due to a low stressor efficacy. In conclusion, echocardiography in mental stress testing permits improved sensitivity, with loss of specificity in comparison with conventional electrocardiographic monitoring.
Modena et al. (Sun,) conducted a observational in Ischemic heart disease (n=56). Echocardiographic monitoring vs. Electrocardiographic monitoring was evaluated on Positive test for ischemia. Echocardiographic monitoring during mental stress testing improved detection of ischemia compared to electrocardiography (37.5% vs 3.6% of patients), with 73.5% sensitivity and 93.3% specificity.