Answers are grounded in this paper and cite their sources.
Transformerless grid-connected inverters with highly efficient and reliable inverter concept (HERIC) and positive-negative neutral point-clamped (PN-NPC) circuit configurations exhibit excellent performance in terms of overall efficiency, common-mode voltage, and alleviated leakage current concern. These inverters are designed to generate only a three-level (3 L) output voltage waveform, thereby reducing the power density of a conversion system. On the other hand, it is well-known that increasing the inverter output voltage levels entails the reduction of the output filter size. In this regard, this article aims to develop a five-level (5 L) inverter output voltage for the improved versions of HERIC-clamped and original PN-NPC inverters. This is achieved with either phase-shifted or level-shifted pulse width modulation technique leading to further quality improvement of ac voltage and current waveforms through increasing the number of output voltage levels. Therefore, a much smaller output filter size can be utilized, while the overall efficiency of the entire system is enhanced. Two laboratory-built SiC-based prototypes for both the proposed HERIC-clamped (1.8 kW) and PN-NPC-5 L (2 kW) inverters have been fabricated to show the feasibility and effectiveness of the proposed solution via experiments.
No takes yet. Share an insight, caveat, or question.
Syasegov et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: