Key result
Single-chamber ICD recipients show ~30% prevalence of dual-chamber indications through 1 year.
Why the study?
What is the prevalence of indications for dual-chamber ICDs in patients treated with single-chamber ICDs?
Cohort (n=153)
Yes
What is the prevalence of indications for dual-chamber ICDs in patients treated with single-chamber ICDs?
Approximately 30% of patients receiving single-chamber ICDs have indications that would potentially benefit from dual-chamber devices, highlighting the need for careful patient selection.
May inform device selection in single-chamber ICD recipients; hypothesis-generating and should not yet change practice.
AIM: This retrospective four-centre study assessed the current indications for dual-chamber implantable cardioverter defibrillators (ICDs) at implant and during a medium-term follow-up period in a group of patients treated by single-chamber ICD in the pre dual-chamber ICD era. METHODS AND RESULTS: The study population consisted of 153 consecutive patients (127 males, mean age 58 +/- 6 years) treated by single-chamber ICD for ventricular tachycardia and/or ventricular fibrillation. Definite indications for having a dual-chamber ICD included the presence of sinus node dysfunction and of second- or third-degree atrioventricular (AV) block, while possible indications were represented by paroxysmal atrial fibrillation or flutter and first-degree AV block. At implant, dual-chamber ICD would appear definitely indicated in 10.5% of cases, and possibly indicated in an additional 17.5% of cases. During 12 +/- 10 months follow-up, such percentages remained stable (11 and 19.5%, respectively). Inappropriate ICD intervention was documented in five of 13 patients (38%), with episodes of paroxysmal atrial fibrillation or flutter. CONCLUSION: In this non-selected study population, a dual-chamber ICD would have potentially benefited approximately 30% of the patients. During medium-term follow-up, there was no progression towards increasing dual-chamber ICD indications. The 15% cumulative incidence of paroxysmal atrial tachyarrhythmias justifies the activation of dedicated detection algorithms.
No takes yet. Share an insight, caveat, or question.
A. Proclemer (2001) conducted a cohort in Ventricular tachycardia and/or ventricular fibrillation treated with single-chamber ICD (n=153). Single-chamber ICD was evaluated on Definite or possible indications for dual-chamber ICD at 1-year follow-up. In patients treated with single-chamber ICDs, approximately 30% had definite or possible indications for a dual-chamber ICD, which remained stable over 1 year of follow-up.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: