Adopting the empirical silicon interatomic potential of Stillinger and Weber, we investigate the effect of the tip profile on the atomic-force microscope images for a prototype system, Si(001)-(2×{}1), and conclude that the tip profile has a profound effect on the observations. We also study relaxation of the surface under the influence of the tip using a many-body energy minimization procedure and find that the force exerted by the tip should be less than {}10^-9 N for the atomic-force microscope to be a nondestructive tool.
No takes yet. Share an insight, caveat, or question.
Abraham et al. (1988) studied this question.