Key result
A smartphone application for telemonitoring in LVAD patients functioned reliably and was graded highly for acceptance and usability over a 4-week period.
Why the study?
Optimal LVAD aftercare requires adequate self-management and hospital support, motivating the evaluation of a newly developed smartphone application for patient telemonitoring.
Is a smartphone application functional, acceptable, and usable for telemonitoring in LVAD patients?
Observational (n=13)
No
Is a smartphone application functional, acceptable, and usable for telemonitoring in LVAD patients?
Answers are grounded in this paper and cite their sources.
A smartphone application for telemonitoring LVAD patients is feasible, functional, and highly accepted, enabling the remote detection of clinical deviations such as out-of-range INRs.
For the success of the treatment with a left ventricular assist device (LVAD), both adequate self-management by the patient and an optimum level of support from the implanting hospital are crucial. A smartphone application has recently been developed within the framework of a European research project for the close monitoring of LVAD patients in order to improve upon their current aftercare situation. Using this new tool, different relevant parameters (eg, weight, international normalized ratio [INR], medication, LVAD parameters, symptoms, and photos of the driveline exit) can be sent daily or as required to a corresponding clinical application at the hospital for evaluation. The objective of this study was to monitor the functionality, acceptance, and usability of this smartphone application in LVAD patients. Prospective single-center study: in total, 13 patients (60 ± 7 years, 92% male, 1027 ± 653 days after LVAD implantation) were requested to test the application for approx. 4 weeks. At the end of the study, all entered data were evaluated and the patients were questioned regarding the acceptance and the usability. During the study period of mean 34 ± 8 days, a total of 453 data records (mean 35 ± 7 per patient) arrived at the hospital. In addition, a total of 19 photos of the driveline exit site were also sent via smartphone. The clinical application registered a total of 160 conspicuities. These comprised 126 INR deviations (target range 2.3-2.8) and 34 symptoms (mainly nosebleeds). The smartphone application functioned reliably, was well received by the patients and was graded highly for acceptance and usability. The results show that smartphone applications can definitely be used to improve aftercare in LVAD therapy in selected patients. Long-term studies are now needed to investigate the extent to which complications can be prevented, healthcare costs reduced, and quality of life increased.
No takes yet. Share an insight, caveat, or question.
Schmidt et al. (2019) conducted an observational in Left ventricular assist device (LVAD) (n=13). Smartphone application for telemonitoring was evaluated on Functionality, acceptance, and usability of the smartphone application. A smartphone application for telemonitoring in LVAD patients functioned reliably and was graded highly for acceptance and usability over a 4-week period.