Analyzes neck biomechanics under vehicle conditions, highlighting implications for safety and design.
Neck injuries remain a critical concern in vehicle safety, particularly during dynamic movements and terrain-induced impacts.Traditional test dummies and wearable devices often fail to capture real-time biomechanical neck responses under such conditions.This study introduces a smart mannequin system designed to measure axial forces and cervical moments in realistic vehicle environments.The system integrates S-type load cells and HX711 amplifiers with a Raspberry Pi 4 for real-time processing, enhanced by Kalman filtering for signal clarity.Calibration was conducted using reference weights from 5 N to 40 N in 5 N increments, with each step validated against a force gauge.The mannequin was tested across various terrains, including straight tracks, inclines, sinusoidal roads, and uneven surfaces, representing realistic military and civilian vehicle conditions.Results showed minimal calibration deviation (2-4 N), with peak force measurements reaching 30.63 N and moment readings up to 1.25 Nm.Higher speeds reduced axial loading on stable tracks, while irregular terrain increased neck strain.The system consistently captured neck loading dynamics, offering a safe, repeatable alternative to human-based testing.Its practical application spans ergonomic vehicle design, occupant safety analysis, and fatigue detection in transport environments.
No takes yet. Share an insight, caveat, or question.
Dawam et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: