Key result
Isometric handgrip contraction increases tibialis anterior motoneuron excitability by ~0.33 pps, demonstrating an impulse-dependent effect.
Why the study?
Persistent inward currents contribution to motoneuron firing increases after remote handgrip contraction, but whether handgrip intensity, duration, or impulse affects tibialis anterior estimates was unknown.
Does isometric handgrip contraction increase tibialis anterior intrinsic motoneuron excitability in healthy adults?
Does isometric handgrip contraction increase tibialis anterior intrinsic motoneuron excitability in healthy adults?
Mean Difference: 0.33 (95% CI 0.16–0.49)
Remote handgrip contraction increases PICs contribution to motoneuron firing in an impulse-dependent manner, suggesting augmented neuromodulatory input onto the spinal cord.
Remote contraction augments spinal motoneuron excitability in healthy adults; leaves open translation to neurological populations or neuromodulation therapies.
Persistent inward currents (PICs) contribution to motoneuron firing in the lower limb typically increase after a remote handgrip contraction, believed to result from diffuse increases of serotonergic input on the spinal cord. We investigated whether handgrip contraction intensity, duration, and/or impulse would affect tibialis anterior estimates of PICs. Multi-channel electromyograms were recorded from the tibialis anterior of 21 participants (18-40 years), during dorsiflexions at 20% of individual’s maximal torque, before and after four handgrip conditions: i) 80%15s , 80% of their maximal handgrip strength sustained for 15s; ii) 40%15s , 40% sustained for 15s; iii) 40%30s , 40% sustained for 30s; and iv) Control (no handgrip). PICs contribution to self-sustained motoneuron firing was estimated with the delta frequency (ΔF) using the paired motor unit analysis. The ‘brace height’, normalised as a percentage of a right triangle (%rTri), was used to quantify the effects of PICs on the non-linearity of firing patterns, representing the neuromodulatory drive (metabotropic regulation of motoneuron excitability) onto the motoneurons. ΔF increased by 0.33 pulses per second (pps; 95%CI 0.16–0.49, d =0.47) after 40%30s and by 0.24 pps (0.09–0.38, d =0.34) after 80%15s but remained unchanged after 40%15s and Control . Similarly, brace height increased by 2.24 %rTri (0.18–4.30, d =0.20) after 40%30s and by 2.45 %rTri (0.64–4.25, d =0.22) after 80%15s; remaining unchanged after 40%15s and Control . The increase in PICs contribution to motoneuron firing induced by a remote handgrip contraction is impulse-dependent rather than intensity or duration. The parallel increases in ΔF and brace height suggest augmented neuromodulatory input onto the spinal cord.
No takes yet. Share an insight, caveat, or question.
Ugliara et al. (2025) studied this question. Isometric handgrip contraction vs. Control (no handgrip) was evaluated on Delta frequency (ΔF) estimating PICs contribution to motoneuron firing (MD 0.33 pps, 95% CI 0.16-0.49). Isometric handgrip contraction at 40% maximal strength for 30s increased tibialis anterior motoneuron excitability (ΔF) by 0.33 pps (95% CI 0.16-0.49), demonstrating an impulse-dependent effect.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: