Key result
Erroneous limb-lead placement in a 45-year-old male produced ST-T changes that mimicked myocardial ischemia, creating a diagnostic dilemma.
Case Report (n=1)
Incorrect placement of ECG limb leads can produce ST-T changes that mimic myocardial ischemia, leading to potential diagnostic dilemmas.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to verify limb-lead placement amid ambiguous ST-T changes; leaves open the population-level frequency of such misdiagnoses.
Most common electrocardiogram (ECG) findings of myocardial ischemia are ST segment deviations & T wave (ST-T) alterations. However, multiple other conditions can cause ST-T changes mimicking ischemia including ventricular hypertrophy, bundle branch block, electrolyte imbalance, drugs, channelopathies, etc. Uncommonly, incorrect placement of limb leads can also produce ST-T changes leading to diagnostic dilemma. We report a case of erroneous limb-lead placement in a 45 years male mimicking ischemic ECG changes.
No takes yet. Share an insight, caveat, or question.
Pradhan et al. (2017) conducted a case report in Chest pain with ST-T changes mimicking ischemia (n=1). Erroneous limb-lead placement was evaluated on ST-T changes mimicking ischemia. Erroneous limb-lead placement in a 45-year-old male produced ST-T changes that mimicked myocardial ischemia, creating a diagnostic dilemma.