Key result
An interval type-II fuzzy-based system for PPG signal quality assessment implemented on a 32-bit ARM Cortex-M4 system-on-chip achieved an overall accuracy of 94.84%.
Why the study?
PPG sensors used in wearable devices present challenges in maintaining good signal quality, which can lead to erroneous results in feature extraction algorithms.
An interval type-II fuzzy-based system for PPG signal quality assessment achieved 94.84% accuracy, demonstrating potential for integration into constrained edge devices for continuous health monitoring.
May support edge-device PPG monitoring; leaves open clinical validation studies.
Wearable technology is having a profound impact in healthcare applications. In this context, one of the main goals of current wearable systems is to provide new devices capable of delivering a greater amount of more precise information. Amongst the different applications, physiological continuous monitoring is becoming one of the most wanted features. In fact, most of the commercially and research grade wearable systems include cardiac activity acquisition, which is generally performed by means of photoplethysmography sensors (PPG). These optical-based sensors present different challenges related to the prevailing of a good signal quality. Thus, in case of dealing with digital processing algorithms which are responsible for extracting different features from such signal, this fact can lead to erroneous results. On this basis, this paper presents an ongoing work towards the design of an interval type-II fuzzy-based system for the PPG signal quality assessment. Moreover, this initial proposed system is implemented into a constrained 32-bit ARM Cortex-M4 system-on-chip. Specifically, the system uses a reduced set of features together with a low complexity fuzzy rule base Mamdani inference model, and is based on a non-overlapping 3-second signal processing window. Results show that the system achieved overall accuracy of 94.84%. The proposed system has great potential for integrating accurate and reliable continuous health monitoring systems into constrained edge devices.
No takes yet. Share an insight, caveat, or question.
Miranda et al. (2022) studied PPG signal quality assessment. Interval type-II fuzzy-based system was evaluated on Overall accuracy. An interval type-II fuzzy-based system for PPG signal quality assessment implemented on a 32-bit ARM Cortex-M4 system-on-chip achieved an overall accuracy of 94.84%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: