Why the study?

Continuous blood pressure monitoring using photoplethysmography faces challenges in real-world wearable scenarios, including poor signal quality, complex model computation, and the need for frequent calibration.

Does a personalized continuous BP tracking pipeline using single-channel PPG accurately monitor blood pressure in wearable scenarios?

Population

134 subjects in daytime, nighttime, and abnormal states

Design

Validation study of a personalized continuous blood pressure tracking pipeline

Authors

CZCongcong ZhouSir Run Run Shaw HospitalXRXianglin RenZhejiang UniversityQWQing WangMinistry of Education

Discussion

Loading...

Member takes

Implication

Enables feasible personalized BP tracking via wearable PPG; leaves open clinical validation before practice adoption.

Structured PICO

Does a personalized continuous BP tracking pipeline using single-channel PPG accurately monitor blood pressure in wearable scenarios?

P
Population
134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states)
I
Intervention
Personalized continuous BP tracking pipeline using single-channel PPG (automatic signal quality grading, SCI-GTCN lightweight BP model, adaptive calibration)
O
Outcome
Blood pressure monitoring accuracy (ME±SD) during rapid BP changes, circadian rhythm fluctuations, and long-term monitoringsurrogate

A novel personalized continuous blood pressure tracking pipeline using single-channel PPG demonstrated accuracy within AAMI standards, showing promise for deployment on wearable healthcare devices.

Limitations

  • subject distribution differs from AAMI standards

Cite This Study

Zhou et al. (2025) studied this question.

synapsesocial.com/papers/6a7cc380cc6f1443deba669fhttps://doi.org/10.1109/jbhi.2025.3535788
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring2016 · 620 citations
  2. 2A Universal Standard for the Validation of Blood Pressure Measuring Devices2018 · 468 citations
  3. 3Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning2021 · 143 citations
  4. 4Continuous Blood Pressure Estimation Using Exclusively Photopletysmography by LSTM-Based Signal-to-Signal Translation2021 · 108 citations
  5. 5An Unobtrusive and Calibration-free Blood Pressure Estimation Method using Photoplethysmography and Biometrics2019 · 98 citations