Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate ( BCP ) through the changes of grafted volume over the time by 3 D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation ( SFE )–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3 D CBCT scans were taken five times at pre‐operatively ( T o), post‐op 1 week ( T 1), 1 month ( T 2), 3 months ( T 3), and 6 months ( T 4). 3D image processing software ( O n D emand3 DTM software) was used for this study. The time sequential change was statistically evaluated. Result 84.32% grafted BCP is maintained until post‐op 6 month ( T 4), and the average volume loss is 207.7 mm 3 (about 0.21 cc). Statistically, a significant volume change (decreasing) was observed in three groups ( T 2– T 1, T 3– T 2, T 4– T 3). Conclusion Biphasic calcium phosphate, as a synthetic material, has high volume stability and is a predictable graft material for the successful SFE . Although some limitations of the 3 D analyzing software program, it is a fast, simple, relatively accurate and promising approach to quantifying long‐term changes in the grafted area.