Key result
Cardiac resynchronization therapy with left ventricular apical pacing leads improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over 4 weeks.
Why the study?
Does cardiac resynchronization therapy improve ejection fraction and QRS duration in neonates with pacing-related left ventricular dysfunction post cardiac surgery?
Case Report (n=1)
No
Does cardiac resynchronization therapy improve ejection fraction and QRS duration in neonates with pacing-related left ventricular dysfunction post cardiac surgery?
Cardiac resynchronization therapy can successfully reverse severe pacing-induced left ventricular dysfunction in infants following congenital heart surgery.
Answers are grounded in this paper and cite their sources.
CRT may aid select neonates with pacing-induced LV dysfunction; hypothesis-generating and requires prospective validation before practice change.
An infant with DiGeorge syndrome, multiple comorbidities, and truncus arteriosus type II underwent repair complicated by heart block necessitating placement of a dual-chamber bipolar pacing system with right ventricular leads and subsequent resynchronization with placement of left ventricular apical pacing leads. Resynchronization therapy improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over the course of 4 weeks with gradual return to normal function and eventual discharge.
No takes yet. Share an insight, caveat, or question.
Jaile et al. (2024) conducted a case report in Pacing-related severe left ventricular dysfunction post cardiac surgery (n=1). Cardiac resynchronization therapy (LV apical pacing leads) was evaluated on Ejection fraction and QRS duration. Cardiac resynchronization therapy with left ventricular apical pacing leads improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over 4 weeks.
Synapse has enriched 10 related papers. Consider them for comparative context: