Key result
ECGVEDNET deep learning model achieves ~86% accuracy for QRS onset delineation within a 5-ms tolerance.
Why the study?
Development of deep ECG delineation models is hindered by limited data availability and ECG morphology variations that degrade model performance.
A novel variational encoder-decoder network, ECGVEDNET, demonstrates high accuracy for ECG delineation of QRS onset and T peak, addressing morphology variations in ECG complexes.
Electrocardiogram (ECG) delineation to identify the fiducial points of ECG segments, plays an important role in cardiovascular diagnosis and care. Whilst deep delineation frameworks have been deployed within the literature, several factors still hinder their development: (a) data availability: the capacity of deep learning models to generalise is limited by the amount of available data; (b) morphology variations: ECG complexes vary, even within the same person, which degrades the performance of conventional deep learning models. To address these concerns, we present a large-scale 12-leads ECG dataset, ICDIRS, to train and evaluate a novel deep delineation model-ECGVEDNET. ICDIRS is a large-scale ECG dataset with 156,145 QRS onset annotations and 156,145 T peak annotations. ECGVEDNET is a novel variational encoder-decoder network designed to address morphology variations. In ECGVEDNET, we construct a well-regularized latent space, in which the latent features of ECG follow a regular distribution and present smaller morphology variations than in the raw data space. Finally, a transfer learning framework is proposed to transfer the knowledge learned on ICDIRS to smaller datasets. On ICDIRS, ECGVEDNET achieves accuracy of 86.28%/88.31% within 5/10 ms tolerance for QRS onset and accuracy of 89.94%/91.16% within 5/10 ms tolerance for T peak. On QTDB, the average time errors computed for QRS onset and T peak are -1.86 ± 8.02 ms and -0.50 ± 12.96 ms, respectively, achieving state-of-the-art performances on both large and small-scale datasets. We will release the source code and the pre-trained model on ICDIRS once accepted.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2024) studied Morphology Variant ECGs. ECGVEDNET (variational encoder-decoder network) was evaluated on Accuracy of QRS onset and T peak delineation within 5/10 ms tolerance. The ECGVEDNET deep learning model achieved an accuracy of 86.28% and 88.31% within 5 and 10 ms tolerance for QRS onset delineation on the ICDIRS dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: