Key result
In patients with persistent atrial fibrillation, right pulmonary vein antrum volume was larger in those with recurrence compared to those without recurrence.
Why the study?
Outcomes of pulmonary vein isolation differ between paroxysmal AF and persistent AF, prompting an analysis of predictors of recurrence after ablation.
Observational (n=250)
No
A larger right pulmonary vein and antrum volume measured by 3D electroanatomical mapping is a significant predictor of atrial fibrillation recurrence after pulmonary vein isolation in patients with persistent atrial fibrillation.
Answers are grounded in this paper and cite their sources.
Larger right pulmonary vein antrum volume was associated with AF recurrence after PVI; hypothesis-generating and requires prospective validation before clinical use.
Pulmonary vein isolation(PVI)is an effective treatment for atrial fibrillation(AF). However, outcomes differ between paroxysmal AF and persistent AF. We analyzed the predictors of recurrence by examining the recurrence group after ablation. Of 372 consecutive patients with AF who underwent PVI between June 2016 and December 2018, we evaluated 250 patients(age, 67±12y, 65% men)whose left atrium(LA)was constructed using the PENTARAY catheter(BioSense Webster, Los Angeles, CA), a multipolar electrode catheter with a novel shape and excellent mapping capability. We measured the LA total volume(LATV), right pulmonary vein+antrum volume(RPAV), left PV+antrum volume(LPAV), LA central volume(LACV), and LA bipolar voltage. Of the 250 patients, 78 had persistent AF(recurrence, 20)and 172 had paroxysmal AF(recurrence, 16). In all patients, LATV, LACV, RPAV, and LPAV were significantly larger in patients with persistent AF than those with paroxysmal AF. The mean LA bipolar voltage in patients with persistent AF was significantly lower than those with paroxysmal AF. In cases of persistent AF, RPAV was significantly larger in the recurrence group than that in the non-recurrence group(15.9±4.8 vs 13.4±5.4ml; P<0.05). In cases of paroxysmal AF, there were no differences in any volume between the recurrence and non-recurrence groups. In conclusion, larger right PV is a predictor of AF recurrence after PVI in patients with persistent AF. The right PV is close to the atrial septum and the septopulmonary bundle, and the expansion of RPAV reflects the disruption of these structures, which may be involved in this result.
No takes yet. Share an insight, caveat, or question.
Furuya et al. (2020) conducted an observational in Atrial Fibrillation (n=250). Large right pulmonary vein antrum volume (RPAV) vs. Smaller right pulmonary vein antrum volume was evaluated on Right pulmonary vein antrum volume (RPAV) in persistent AF patients with vs without recurrence (p=<0.05). In patients with persistent atrial fibrillation, right pulmonary vein antrum volume was larger in those with recurrence compared to those without recurrence.
Synapse has enriched 10 related papers. Consider them for comparative context: