Scattered radiation and grid performance were investigated for contrast-enhanced dual-energy mammography (CEDM) using Monte Carlo simulations through analysis of the scatter-to-primary ratio ( S P R ), grid selectivity ( Σ ), Bucky factor ( B F ), and signal-to-noise ratio improvement factor ( K SNR ). These parameters were investigated for different grid designs: a 5:1 linear grid ( G 5 2 D ) and a 4:1 cellular grid ( G 4 2 D ), both employed for 2D mammography, and 5:1 and 11:1 linear grids ( G 5 B T and G 1 1 B T , respectively), both employed for breast tomosynthesis. Different breast thicknesses, compositions, along with direct (aSe) and indirect (CsI) image receptors were investigated. Additionally, different x-ray spectra were also evaluated, for low-energy (LE) imaging, with the W/Rh and W/Ag combinations for tube potentials between 24–40 kV, and for high-energy imaging (HE), with W/Cu, Mo/Cu and W/Ti combinations between 40–49 kV. The results showed that the HE spectra yielded higher S P R values than the LE spectra, regardless of grid usage. The dependence of S P R on the tube potential varied between the LE and HE spectra and the image receptor. For the LE spectra, the G 1 1 B T and G 4 2 D grids exhibited lower S P R values, whereas the 5:1 linear grids exhibited higher values. For the HE spectra, higher S P R values were observed with the G 5 B T and G 4 2 D grids and lower values were observed with the G 1 1 B T grid. The grid selectivity decreased with tube potential and breast thickness. For the LE beam, the selectivity was highest for the G 1 1 B T and G 4 2 D grids, and lowest for the G 5 B T grid. For the HE beam, the selectivity was highest for G 1 1 B T and G 5 B T grids and lowest for the G 5 B T and G 4 2 D grids. The Bucky factor decreased with tube potential, but increased with increasing breast thickness. Higher B F values were observed for the breast tomosynthesis grids than for the 2D imaging grids for both the LE and HE beams. K SNR values increased with tube potential for the LE anode/filter combinations, whereas for the HE combinations, the image receptor influenced this relationship. K SNR values also increased with breast thickness, with the G 4 2 D and G 1 1 B T grids showing higher values for the LE and HE spectra, respectively. Lower K SNR values were observed for the G 5 B T grid for both LE and HE beams. The concurrent analysis of K SNR and B F indicated that, for the LE spectrum, the G 4 2 D cellular grid exhibited better performance, followed by the G 5 2 D , whereas the G 5 B T and G 1 1 B T grids performed similarly. For the HE spectrum, the G 4 2 D and G 5 2 D grids demonstrated comparable and better overall performance, followed by the G 1 1 B T and G 5 B T grids. The results of this study demonstrate that, in CEDM, the properties of scattered radiation and grid performance differ significantly between the low- and high-energy spectra used. • X-ray scatter-to-primary ratio differs between low- and high-energy images. • Without a grid, scatter-to-primary ratio also differs between image receptors. • Grid performance differs between low- and high-energy images. • The 4:1 cellular grid demonstrated superior overall performance for CEDM.
No takes yet. Share an insight, caveat, or question.
Cunha et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: