Key result
Robotic epicardial off-pump pulmonary vein isolation successfully restored permanent sinus rhythm in 76.9% (10 of 13) of patients with paroxysmal atrial fibrillation.
Why the study?
Does robotic epicardial off-pump pulmonary vein isolation restore sinus rhythm in patients with paroxysmal atrial fibrillation?
Observational (n=13)
No
Does robotic epicardial off-pump pulmonary vein isolation restore sinus rhythm in patients with paroxysmal atrial fibrillation?
Robotic epicardial off-pump pulmonary vein isolation is a feasible procedure that successfully restored sinus rhythm in 76.9% of patients with paroxysmal atrial fibrillation in this initial experience.
Answers are grounded in this paper and cite their sources.
May support feasibility in paroxysmal AF; leaves open need for randomized trials before adoption.
OBJECTIVE: : To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. METHODS: : Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ± 31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. RESULTS: : The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. CONCLUSIONS: : Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Casselman et al. (2006) conducted an observational in Paroxysmal atrial fibrillation (n=13). Robotic epicardial off-pump pulmonary vein isolation was evaluated on Restoration of permanent sinus rhythm. Robotic epicardial off-pump pulmonary vein isolation successfully restored permanent sinus rhythm in 76.9% (10 of 13) of patients with paroxysmal atrial fibrillation.
Synapse has enriched 10 related papers. Consider them for comparative context: