Key result
An integrated system for automated video segmentation of carotid plaque achieved a true-positive fraction of 78.12% and an overlap index of 71.5% compared to expert manual segmentation.
Why the study?
Does an integrated system for automated segmentation of atherosclerotic carotid plaque in ultrasound video match the accuracy of expert manual segmentation?
Does an integrated system for automated segmentation of atherosclerotic carotid plaque in ultrasound video match the accuracy of expert manual segmentation?
The proposed integrated system for automated video segmentation of carotid plaque in ultrasound videos demonstrates satisfactory accuracy compared to expert manual segmentation.
May facilitate efficient carotid plaque assessment in ultrasound; leaves open prospective validation for clinical use.
The degree of stenosis of the common carotid artery (CCA) but also the characteristics of the arterial wall including plaque size, composition and elasticity represent important predictors used in the assessment of the risk for future cardiovascular events. This paper proposes and evaluates an integrated system for the segmentation of atherosclerotic carotid plaque in ultrasound video of the CCA based on normalization, speckle reduction filtering (with the hybrid median filter) and parametric active contours. The algorithm is initialized in the first video frame of the cardiac cycle with human assistance and the moving atherosclerotic plaque borders are tracked and segmented in the subsequent frames. The algorithm is evaluated on 10 real CCA digitized videos from B-mode longitudinal ultrasound segments and is compared with the manual segmentations of an expert, for every 20 frames in a time span of 3-5 seconds, covering in general 2 cardiac cycles. The segmentation results are very satisfactory with a true negative fraction (TNF) of 79.3%, a true-positive fraction (TPF) of 78.12%, a false-positive fraction (FPF) of 6.7% and a false-negative fraction (FNF) of 19.6% between the ground truth and the presented plaque segmentations, a Williams index (KI) of 80.3%, an overlap index of 71.5%, a specificity of 0.88±0.09, a precision of 0.86±0.10 and an effectiveness measure of 0.77±0.09. The results show that integrated system investigated in this study could be successfully used for the automated video segmentation of the carotid plaque.
No takes yet. Share an insight, caveat, or question.
Loizou et al. (2012) studied Atherosclerotic carotid plaque (n=10). Integrated system for automated video segmentation vs. Manual segmentations of an expert was evaluated on Segmentation accuracy (true-positive fraction, overlap index, etc.). An integrated system for automated video segmentation of carotid plaque achieved a true-positive fraction of 78.12% and an overlap index of 71.5% compared to expert manual segmentation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: