Key result
Routine use of ultrasound guidance during placement of internal jugular venous access ports resulted in 0% post-procedure pneumothoraces or hemothoraces across 500 cases.
Why the study?
Does ultrasound guidance prevent pneumothorax and hemothorax during placement of implantable venous access ports in patients requiring chronic venous access?
Observational (n=500)
No
Does ultrasound guidance prevent pneumothorax and hemothorax during placement of implantable venous access ports in patients requiring chronic venous access?
Routine use of ultrasound guidance during internal jugular venous access port placement eliminates the risk of pneumothorax and hemothorax.
Answers are grounded in this paper and cite their sources.
May support ultrasound guidance for internal jugular port placement; hypothesis-generating and requires randomized confirmation.
Implantable venous access ports are essential for patients requiring chronic venous access. Ultrasound guided catheter placement has been recognized as a valuable adjunct for reducing complications during placement of access ports in the radiology and critical care medicine literature. We reviewed the medical records of patients undergoing insertion of implantable venous access ports from June 2006 through June 2009. All procedures were performed using ultrasound guidance with the internal jugular vein as the access site. There were 500 implantable venous access ports placed and included for review. There were no post-procedure pneumothoraces or hemothoraces. Carotid puncture was documented in 4 (0.8%)cases. Routine use of ultrasound guidance during placement of implantable venous access ports has eliminated the complications of pneumothorax and hemothorax during placement of internal jugular venous access ports on our vascular surgery service. Elimination of these complications and decreased use of chest x-rays should also provide increased cost savings for this procedure.
No takes yet. Share an insight, caveat, or question.
Fankhauser et al. (2013) conducted an observational in Patients requiring chronic venous access (n=500). Ultrasound guidance during placement of implantable venous access ports was evaluated on Post-procedure pneumothoraces or hemothoraces. Routine use of ultrasound guidance during placement of internal jugular venous access ports resulted in 0% post-procedure pneumothoraces or hemothoraces across 500 cases.
Synapse has enriched 10 related papers. Consider them for comparative context: