Key result
4D flow MRI-derived measures of uterine artery pulsatility index and blood flow performed comparably to Doppler ultrasound in predicting the composite of pre-eclampsia and small-for-gestational-age neonate.
Why the study?
Clinical uterine artery hemodynamic assessment is limited to Doppler ultrasound, so researchers sought to validate 4D flow MRI measurements by evaluating their association with pregnancy outcomes relative to ultrasound metrics.
Does 4D flow MRI measurement of uterine artery blood flow predict composite adverse pregnancy outcomes comparably to Doppler ultrasound in pregnant women?
Cross-Sectional (n=87)
No
Does 4D flow MRI measurement of uterine artery blood flow predict composite adverse pregnancy outcomes comparably to Doppler ultrasound in pregnant women?
Effect estimate: AUC 0.737 for MRI-PI, AUC 0.731 for US-PI, AUC 0.694 for MRI-flow
p-value: p=0.87
4D flow MRI provides physiologically relevant measurements of uterine artery hemodynamics that are comparable to Doppler ultrasound in distinguishing pregnancies at risk for pre-eclampsia or small-for-gestational-age neonates.
Comparable 4D flow MRI metrics do not yet support practice change; leaves open prospective validation versus Doppler in larger cohorts.
OBJECTIVES: Clinical assessment of uterine artery (UtA) hemodynamics is currently limited to Doppler ultrasound (US) velocimetry. We have demonstrated previously the feasibility of applying four-dimensional (4D) flow magnetic resonance imaging (MRI) to evaluate UtA hemodynamics during pregnancy, allowing flow quantification of the entire course of the vessel. In this study, we sought to further validate the physiological relevance of 4D flow MRI measurement of UtA blood flow by exploring its association with pregnancy outcome relative to US-based metrics. METHODS: Recruited into this prospective, cross-sectional study were 87 women with a singleton pregnancy who underwent 4D flow MRI between May 2016 and April 2019 to measure the UtA pulsatility index (MRI-PI) and blood flow rate (MRI-flow, in mL/min). UtA-PI was also measured using US (US-PI). The primary outcome was a composite (COMP) of pre-eclampsia (PE) and/or small-for-gestational-age (SGA) neonate, and secondary outcomes were PE and SGA neonate individually. We assessed the ability of MRI-flow, MRI-PI and US-PI to distinguish between outcomes, and evaluated whether MRI-flow changed as gestation progressed. RESULTS: Following 4D flow postprocessing and exclusions from the analysis, 74 women had 4D flow MRI data analyzed for both UtAs. Of these, 18 developed a COMP outcome: three developed PE only, 11 had a SGA neonate only and four had both. A comparison of the COMP group vs the no-COMP group found no differences in maternal age, body mass index, nulliparity, gravidity or race. For 66 of the 74 subjects, US data were also available. In these subjects, both median MRI-PI (0.95 vs 0.70; P < 0.01) and median US-PI (0.95 vs 0.73; P < 0.01) were significantly increased in subjects in the COMP group compared with those in the no-COMP group. The UtA blood-flow rate, as measured by MRI, did not increase significantly from the second to the third trimester (median flow (interquartile range (IQR)), 543 (419-698) vs 575 (440-746) mL/min; P = 0.77), but it was significantly lower overall in the COMP compared with the no-COMP group (median flow (IQR), 486 (366-598) vs 624 (457-749) mL/min; P = 0.04). The areas under the receiver-operating-characteristics curves for MRI-flow, MRI-PI and US-PI in predicting COMP were not significantly different (0.694, 0.737 and 0.731, respectively; P = 0.87). CONCLUSIONS: 4D flow MRI can yield physiological measures of UtA blood-flow rate and PI that are associated with adverse pregnancy outcome. This may open up new avenues in the future to expand the potential of this technique as a robust tool with which to evaluate UtA hemodynamics in pregnancy.
No takes yet. Share an insight, caveat, or question.
Hwuang et al. (2020) conducted a cross-sectional in Singleton pregnancy (n=87). 4D flow MRI vs. Doppler ultrasound was evaluated on Composite of pre-eclampsia (PE) and/or small-for-gestational-age (SGA) neonate (AUC 0.737 for MRI-PI, AUC 0.731 for US-PI, AUC 0.694 for MRI-flow, p=0.87). 4D flow MRI-derived measures of uterine artery pulsatility index and blood flow performed comparably to Doppler ultrasound in predicting the composite of pre-eclampsia and small-for-gestational-age neonate.