It is well known that electrostrictive strains are proportional to the square of the applied electric field. It therefore appeared reasonable to assume that for some polymeric materials, a large acoustic thickness response, d T , \[ ( {d_T = {{dS}}{{dE}}} ) \] might be obtained by application of high dc bias fields, ∼ 20 MV/m, to a film while driving the film with an ac signal to access the high slope region of the electrostrictive strain vs. applied field curve. Previous studies of crystallizing poly(vinylidene fluoride) (PVF 2 ) from solution under high electric fields have demonstrated that gel‐like samples of PVF 2 with high content of the plasticizer tricresyl phosphate (TCP) could be subjected to electric fields as high as ∼ 100 MV/m. Using this type of heavily plasticized PVF 2 d T values ∼ 4 Å/V were obtained. Values of 9 Å/V were obtained for a certain class of thermoplastic elastomer (i.e., a polyurethane). These d T values are considerably greater than those obtained from conventional piezoelectric ceramic materials. In addition, large elastic strains (> 3%) were observed as a function of applied dc field.