Key result
Deep learning model analyzing SPECT-MPI achieves ~0.77 AUC for CAD diagnosis, outperforming expert readers.
Why the study?
Visual interpretation of SPECT myocardial perfusion imaging for CAD diagnosis is time-consuming and experience-dependent.
Does deep learning analysis of SPECT-MPI polar maps improve automated diagnosis of coronary artery disease compared to expert reader assessment and invasive coronary angiography?
Cross-Sectional (n=940)
No
Does deep learning analysis of SPECT-MPI polar maps improve automated diagnosis of coronary artery disease compared to expert reader assessment and invasive coronary angiography?
Absolute Event Rate: 0.77% vs 0.62%
Deep learning models trained on SPECT-MPI polar maps using semi-supervised and transfer learning strategies can achieve diagnostic accuracy for CAD comparable to expert readers.
May enhance SPECT-MPI CAD detection over experts; leaves open prospective outcome trials before clinical adoption.
BACKGROUND: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is a well-established modality for noninvasive diagnostic assessment of coronary artery disease (CAD). However, the time-consuming and experience-dependent visual interpretation of SPECT images remains a limitation in the clinic. PURPOSE: We aimed to develop advanced models to diagnose CAD using different supervised and semi-supervised deep learning (DL) algorithms and training strategies, including transfer learning and data augmentation, with SPECT-MPI and invasive coronary angiography (ICA) as standard of reference. MATERIALS AND METHODS: A total of 940 patients who underwent SPECT-MPI were enrolled (281 patients included ICA). Quantitative perfusion SPECT (QPS) was used to extract polar maps of rest and stress states. We defined two different tasks, including (1) Automated CAD diagnosis with expert reader (ER) assessment of SPECT-MPI as reference, and (2) CAD diagnosis from SPECT-MPI based on reference ICA reports. In task 2, we used 6 strategies for training DL models. We implemented 13 different DL models along with 4 input types with and without data augmentation (WAug and WoAug) to train, validate, and test the DL models (728 models). One hundred patients with ICA as standard of reference (the same patients in task 1) were used to evaluate models per vessel and per patient. Metrics, such as the area under the receiver operating characteristics curve (AUC), accuracy, sensitivity, specificity, precision, and balanced accuracy were reported. DeLong and pairwise Wilcoxon rank sum tests were respectively used to compare models and strategies after 1000 bootstraps on the test data for all models. We also compared the performance of our best DL model to ER's diagnosis. RESULTS: In task 1, DenseNet201 Late Fusion (AUC = 0.89) and ResNet152V2 Late Fusion (AUC = 0.83) models outperformed other models in per-vessel and per-patient analyses, respectively. In task 2, the best models for CAD prediction based on ICA were Strategy 3 (a combination of ER- and ICA-based diagnosis in train data), WoAug InceptionResNetV2 EarlyFusion (AUC = 0.71), and Strategy 5 (semi-supervised approach) WoAug ResNet152V2 EarlyFusion (AUC = 0.77) in per-vessel and per-patient analyses, respectively. Moreover, saliency maps showed that models could be helpful for focusing on relevant spots for decision making. CONCLUSION: Our study confirmed the potential of DL-based analysis of SPECT-MPI polar maps in CAD diagnosis. In the automation of ER-based diagnosis, models' performance was promising showing accuracy close to expert-level analysis. It demonstrated that using different strategies of data combination, such as including those with and without ICA, along with different training methods, like semi-supervised learning, can increase the performance of DL models. The proposed DL models could be coupled with computer-aided diagnosis systems and be used as an assistant to nuclear medicine physicians to improve their diagnosis and reporting, but only in the LAD territory. CLINICAL TRIAL NUMBER: Not applicable.
No takes yet. Share an insight, caveat, or question.
Hajianfar et al. (2025) conducted a cross-sectional in Coronary artery disease (n=940). Deep learning models for SPECT-MPI analysis vs. Expert reader assessment was evaluated on Area under the receiver operating characteristics curve (AUC) for CAD diagnosis based on ICA (per-patient). A deep learning model analyzing SPECT-MPI polar maps achieved an AUC of 0.77 for predicting invasive coronary angiography-based CAD diagnosis per-patient, compared to 0.62 for expert readers.