PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 24, 2009Journal of Applied Physiology21 citations

Three-dimensional alignment of the aggregated myocytes in the normal and hypertrophic murine heart

View Full Paper
BSBoris SchmittKFKatsiaryna FedaravaJFJan Falkenberg

Key Result

Angiotensin II-induced ventricular hypertrophy in mice resulted in significantly larger intruding angles (P<0.001) and smaller helical angles (P<0.01) of aggregated myocytes compared with controls.

Structured PICO

Does ventricular hypertrophy alter the three-dimensional alignment of aggregated myocytes in murine hearts as assessed by DT-MRI?

P
Population
14 mice (7 with angiotensin II-induced ventricular hypertrophy and 7 controls) evaluated using diffusion tensor magnetic resonance imaging.
I
Intervention
Diffusion tensor magnetic resonance imaging (DT-MRI) at 3.0 Tesla of explanted hypertrophic hearts
C
Comparator
DT-MRI of explanted normal control hearts
O
Outcome
Three-dimensional orientation of aggregated myocytes (helical angles and transmural courses/intruding angles)surrogate

DT-MRI demonstrates significant alterations in the three-dimensional alignment, specifically helix and intruding angles, of myocytes in hypertrophic murine hearts compared to normal hearts.

Main Result

p-value: p=<0.001

Abstract

Several observations suggest that the transmission of myocardial forces is influenced in part by the spatial arrangement of the myocytes aggregated together within ventricular mass. Our aim was to assess, using diffusion tensor magnetic resonance imaging (DT-MRI), any differences in the three-dimensional arrangement of these myocytes in the normal heart compared with the hypertrophic murine myocardium. We induced ventricular hypertrophy in seven mice by infusion of angiotensin II through a subcutaneous pump, with seven other mice serving as controls. DT-MRI of explanted hearts was performed at 3.0 Tesla. We used the primary eigenvector in each voxel to determine the three-dimensional orientation of aggregated myocytes in respect to their helical angles and their transmural courses (intruding angles). Compared with controls, the hypertrophic hearts showed significant increases in myocardial mass and the outer radius of the left ventricular chamber (P < 0.05). In both groups, a significant change was noted from positive intruding angles at the base to negative angles at the ventricular apex (P < 0.01). Compared with controls, the hypertrophied hearts had significantly larger intruding angles of the aggregated myocytes, notably in the apical and basal slices (P < 0.001). In both groups, the helical angles were greatest in midventricular sections, albeit with significantly smaller angles in the mice with hypertrophied myocardium (P < 0.01). The use of DT-MRI revealed significant differences in helix and intruding angles of the myocytes in the mice with hypertrophied myocardium.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Schmitt et al. (2009) studied Ventricular hypertrophy (n=14). Angiotensin II infusion vs. Controls was evaluated on Intruding angles of aggregated myocytes (p=<0.001). Angiotensin II-induced ventricular hypertrophy in mice resulted in significantly larger intruding angles (P<0.001) and smaller helical angles (P<0.01) of aggregated myocytes compared with controls.

synapsesocial.com/papers/6a2082c3cd682a52c6f89c70https://doi.org/10.1152/japplphysiol.00275.2009
Ask AI
Helpful
Bookmark
Share
View Full Paper