Key result
Temperature-controlled flutter ablation using an 8-mm tip catheter and up to 150 W achieved 94% acute and 88% long-term success, but was associated with a 12% rate of pops.
Why the study?
Does temperature-controlled radiofrequency ablation using an 8-mm tip catheter and up to 150 W improve success rates in patients with common atrial flutter?
Population
50 new cases with either typical atrial flutter alone or predominant flutter as the indication; no combined…
Design
Case_series
Authors
Loading...
May warrant caution with high-power settings due to pop risk; leaves open safety and efficacy of temperature-controlled ablation pending controlled trials.
Observational (n=50)
Does temperature-controlled radiofrequency ablation using an 8-mm tip catheter and up to 150 W improve success rates in patients with common atrial flutter?
Using up to 150 W for atrial flutter ablation achieves high success rates but is associated with a notable risk of steam pops and potential perforation.
Hillock et al. (2005) conducted an observational in Atrial flutter (n=50). Temperature-controlled flutter ablation using an 8-mm tip catheter was evaluated on Acute procedural success. Temperature-controlled flutter ablation using an 8-mm tip catheter and up to 150 W achieved 94% acute and 88% long-term success, but was associated with a 12% rate of pops.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: