Key result
CMR shows excellent agreement with TTE for measuring aortic valve area and detecting strain impairment.
Why the study?
Although TTE is recommended to evaluate AS, CMR planimetry is used when findings are inconclusive, warranting comparison between TTE and CMR in severe AS with normal LV function.
Does cardiac magnetic resonance (CMR) provide reliable aortic valve area and myocardial strain measurements compared to transthoracic echocardiography (TTE) in patients with severe aortic stenosis and normal LV function?
Observational (n=48)
Single-blind
No
Does cardiac magnetic resonance (CMR) provide reliable aortic valve area and myocardial strain measurements compared to transthoracic echocardiography (TTE) in patients with severe aortic stenosis and normal LV function?
Effect estimate: ICC 0.932 (95% CI 0.829-0.973)
p-value: p=<0.001
CMR serves as a reliable noninvasive alternative to TTE for measuring aortic valve area and can detect early subclinical myocardial dysfunction in severe aortic stenosis.
CMR may support AVA assessment when TTE is limited in severe AS; leaves open clinical utility of strain correlations pending prospective validation.
Background: Transthoracic echocardiography (TTE) is the recommended imaging technique for the evaluation of patients with aortic stenosis (AS). However, in cases with inconclusive findings, cardiac magnetic resonance (CMR) planimetry is used to grade AS severity. This study aimed to compare the results derived from TTE and CMR in patients with severe AS with normal left ventricular (LV) function. Methods: test, intraclass correlation coefficient (ICC), and Pearson correlation. P<0.05 was considered statistically significant. Results: An excellent agreement was found in AVA values derived from CMR and TTE with an average ICC of 0.932 (95% CI=0.829-0.973). There was a significant difference in LV-GLS, LV global radial strain (GRS), right ventricular (RV) GRS, and RV global circumferential strain between the groups. A good correlation was found between CMR- and TTE-derived GLS with an average ICC of 0.721 (95% C=0.255-0.896). The mean aortic valve pressure gradient in TTE had a significant inverse linear correlation with LV-GRS in CMR (r=-0.537). All P values were <0.05. Conclusion: There was a good agreement between AVA and strain values derived from cardiac MRI and TTE. The myocardial strain was impaired in patients with severe AS and normal LV function and correlated with disease severity.
No takes yet. Share an insight, caveat, or question.
Rezaeian et al. (2023) conducted an observational in Severe aortic stenosis with normal left ventricular function (n=48). Cardiac magnetic resonance (CMR) vs. Transthoracic echocardiography (TTE) was evaluated on Agreement between aortic valve area (AVA) values derived from CMR planimetry and TTE (ICC 0.932, 95% CI 0.829-0.973, p=<0.001). Cardiac magnetic resonance demonstrated excellent agreement with transthoracic echocardiography for evaluating aortic valve area (ICC 0.932) and detecting subclinical myocardial strain impairment.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: