Key result
Ventricular mechanical contraction with stretch-activated current increased QRS duration by 23% and QT interval by 5% compared to a static heart model.
Why the study?
Does ventricular mechanical contraction affect the morphology and characteristics of the 12-lead ECG in a simulated human ventricle model?
Does ventricular mechanical contraction affect the morphology and characteristics of the 12-lead ECG in a simulated human ventricle model?
Mechanical contraction of the heart, particularly through stretch-activated currents, significantly alters ECG morphology, suggesting that mechanical contraction should be considered in clinical ECG interpretation.
Should not yet inform ECG interpretation; leaves open translation of stretch effects from animal models to humans.
Introduction: The 12-lead electrocardiogram (ECG) is the most widely-used tool for the detection and diagnosis of cardiac conditions including myocardial infarction and ischemia. It has therefore been a focus of cardiac modeling. However, the most contemporary in silico ECG investigations of the intact heart have assumed a static heart and ignored the mechanical contraction that is an essential component of cardiac function. The aim of this study was to utilize electromechanically coupled human ventricle models to explore the consequences of ventricular mechanical contraction on the ECG profiles. Methods and Results: Biophysically detailed human ventricular cell models incorporating contractile activity and a stretchactivated current (Isac) were incorporated into a 3D human ventricular model within a human torso, from which 12-lead ECGs were computed at a stimulation rate of 1 Hz. Compared to the static model, ventricular contraction without Isac had little effect on the QRS complex, but shifted the T-wave peak leftwards and reduced its peak amplitude. With Isac, ventricular mechanical contraction increased the QRS duration by 23% and QT interval by 5%. Conclusion: Mechanical contraction of the heart has a significant effect on the morphology and characteristics of the ECG particularly on the T-wave. The alteration of the cell membrane kinetics by stretch via Isac further exacerbates these effects. Our simulation data suggest that mechanical contraction should be considered in the interpretation of ECGs in pathological conditions, especially those in which mechanical contraction of the heart is impaired.
No takes yet. Share an insight, caveat, or question.
Adeniran et al. (2013) studied Healthy (n=1). Ventricular mechanical contraction with stretch-activated current (Isac) vs. Static heart model was evaluated on QRS duration and QT interval. Ventricular mechanical contraction with stretch-activated current increased QRS duration by 23% and QT interval by 5% compared to a static heart model.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: