The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to a variety of practical positioning applications is described. A novel pulse width modulation (PWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. The open-loop characteristic is shown both theoretically and experimentally to be near symmetrical. A comparison of the open- and closed-loop responses of standard PWM techniques and that of the novel PWM technique shows that there has been a significant improvement in the control. A linear process model is obtained from experimental data using system identification. A proportional integral derivative controller with added friction compensation and position feedforward has been successfully implemented. A worst case steady-state accuracy of 0.21 mm was achieved with a rise time of 180 ms for step inputs from 0.11 to 64 mm. Following errors to 64-mm S-curve profiles were less than 2.0 mm. The controller is robust to a sixfold increase in the system mass. The actuator's overall performance is comparable to that achieved by other researchers using servo valves.
No takes yet. Share an insight, caveat, or question.
Varseveld et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: