Key result
Zero-fluoro, apron-less repeat PVI achieves 100% procedural success without major complications.
Why the study?
The feasibility and safety of a zero-fluoro approach for repeat AF procedures after initial cryoballoon ablation had not been established.
Is a zero-fluoro, apron-less approach using radiofrequency energy feasible and safe for repeat pulmonary vein isolation in patients with recurrent atrial fibrillation after initial cryoballoon ablation?
Observational (n=50)
No
Is a zero-fluoro, apron-less approach using radiofrequency energy feasible and safe for repeat pulmonary vein isolation in patients with recurrent atrial fibrillation after initial cryoballoon ablation?
A zero-fluoro, apron-less approach using intracardiac echocardiography and 3D mapping for repeat atrial fibrillation ablation is feasible, safe, and provides favorable midterm rhythm control.
Answers are grounded in this paper and cite their sources.
May support zero-fluoro repeat PVI in select patients; leaves open randomized trials for efficacy confirmation.
We aimed to investigate the feasibility and safety of zero-fluoro approach for the repeat atrial fibrillation (AF) procedures after initial cryoballoon (CB) ablation. We have performed a retrospective study on patients that have undergone repeat pulmonary vein isolation (PVI) procedures in our institution since zero-fluoro program was initiated in 2020. All patients received CB ablation for the initial procedure. Repeat procedures were performed under conscious sedation and with intracardiac echo (ICE) and 3D mapping system - without the use of fluoroscopy and lead aprons. We have analysed in total 50 patients (76% male, 57.9 ± 10.2 years old), 50% of which suffered from paroxysmal AF. All procedures were successfully performed without the use of fluoroscopy. The mean procedure time was 93.9 ± 27.1 min and the mean RF time was 825 ± 468 s. The mean of 0.98 ± 0.91 veins was reconnected per patient and 36% of patients did not have PV reconnections. In all patients successful PV isolation was performed, confirmed by entry and exit block. No major periprocedural complications were observed. After the mean follow up of 12.5 ± 3.4 months: 68% of mixed AF population patients were free from AF after one year. In our cohort of patients, zero-fluoro, apron-less approach for repeat PVI procedures after index cryoballoon ablation proved to be feasible and safe. Index CB ablation resulted with low rates of PV reconnections and mid-term results after repeat procedures are favourable.
No takes yet. Share an insight, caveat, or question.
Velagić et al. (2025) conducted an observational in Repeat atrial fibrillation after initial cryoballoon ablation (n=50). Zero-fluoro, apron-less approach was evaluated on Feasibility and safety. A zero-fluoro, apron-less approach for repeat pulmonary vein isolation was feasible and safe, achieving 100% procedural success with no major complications and 68% freedom from AF at one year.
Synapse has enriched 10 related papers. Consider them for comparative context: