Key result
A zero-fluoroscopic strategy using a 3D-electroanatomical mapping system significantly reduced median fluoroscopy dose to 0 mGy compared to 13.5 mGy with a conventional approach (p<0.001).
Why the study?
Does a zero-fluoroscopic approach using a 3D mapping system reduce radiation exposure and maintain safety in patients undergoing ablation for supraventricular tachycardias?
Cohort (n=92)
No
Does a zero-fluoroscopic approach using a 3D mapping system reduce radiation exposure and maintain safety in patients undergoing ablation for supraventricular tachycardias?
Absolute Event Rate: 0% vs 13.5%
p-value: p=<0.001
A zero-fluoroscopic approach using a novel 3D mapping system for SVT ablation is feasible, safe, and significantly reduces radiation exposure without prolonging procedure times.
Supports radiation minimization in SVT ablation; leaves open randomized trials before practice change.
Zero- and near-zero-fluoroscopic ablation techniques reduce the harmful effects of ionizing radiation during invasive electrophysiology procedures. We aimed to test the feasibility and safety of a zero-fluoroscopic strategy using a novel integrated magnetic and impedance-based electroanatomical mapping system for radiofrequency ablation (RFA) of supraventricular tachycardias (SVTs). We retrospectively studied 92 consecutive patients undergoing electrophysiology studies with/without RFA for supraventricular tachycardia (SVT) performed by a single operator at a single center. The first 42 (Group 1) underwent a conventional fluoroscopic-guided approach and the second 50 (Group 2) underwent a zero-fluoroscopic approach using the Ensite Precision™ 3-D magnetic and impedance-based mapping system (Abbott Inc). Group 1 comprised 14 AV-nodal re-entrant tachycardia (AVNRT), 12 typical atrial flutter, 4 accessory pathway (AP), 2 atrial tachycardia (AT), and 9 diagnostic EP studies (EPS). Group 2 comprised 16 AVNRT, 17 atrial flutter, 6 AP, 3 AT, 2 AV-nodal ablations, and 7 EPS. A complete zero-fluoroscopic approach was achieved in 94% of Group 2 patients. All procedures were acutely successful, and no complications occurred. There was a significant reduction in fluoroscopy dose, dose area product, and time (p < 0.0001, for all), with no difference in procedure times. Ablation time for typical atrial flutter was shorter in Group 2 (p = 0.006). A zero-fluoroscopic strategy for diagnosis and treatment of SVTs using this novel 3D-electroanatomical mapping system is feasible in majority of patients, is safe, reduces ionizing radiation exposure, and does not compromise procedural times, success rates, or complication rates.
No takes yet. Share an insight, caveat, or question.
Walsh et al. (2018) conducted a cohort in Supraventricular tachycardia (SVT) (n=92). Zero-fluoroscopic approach using Ensite Precision 3-D mapping system vs. Conventional fluoroscopic-guided approach was evaluated on Fluoroscopy dose (mGy) (p=<0.001). A zero-fluoroscopic strategy using a 3D-electroanatomical mapping system significantly reduced median fluoroscopy dose to 0 mGy compared to 13.5 mGy with a conventional approach (p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: