Answers are grounded in this paper and cite their sources.
In this paper, grid-forming and reduced-order modeling of a novel pumped hydro energy storage-integrated wind power generator (PHES-WPG) is developed and validated. The PHES-WPG makes use of Hopf oscillator-based DFIG grid-forming and mirror-principle-based reduced-order modeling approaches. For the pumped-hydro storage, the wind and water towers in hilly regions are combined as upper reservoir, and the nearest lake is used as lower reservoir. Rather than directly connected to the grid, the doubly fed induction generator (DFIG) rotor-side AC-DC-AC system is taken as a conversion system of permanent magnet synchronous machine (PMSM)-based hydraulic storage system. By utilizing DFIG kinetic energy and installing supercapacitors at DC-links, combined matching and Hopf oscillator controls are further developed to enable better amplitude-phase motion of the GFM-DFIG. This leads to the self-synchronization of GFM-DFIG with external power grid and facilitates its faults-ride through capacity. Furthermore, a reduced-order modelling approach of the PHES-WPG based on the mirror principle is developed to analyze the inertia and primary frequency responses in a convenient manner. To accelerate the simulation speed, a comprehensive transients-dynamics simulation framework of the PHES-WPG is implemented. Through the comparisons of variant approaches and parameters, the effectiveness of the advanced GFM and reduced-order modelling method is validated. The advantages of the proposed PHES-WPG are verified via diverse studies that include tolerated fault currents, scheduled dispatching capacities, primary frequency regulations as well as simple economics analysis. • A compact PHES-based wind power generator (WPG) is proposed in which the wind turbine and water towers are combined as the PHES upper reservoir. • The Hopf oscillator-based DFIG grid-forming (GFM) functions are developed where the inertia matching and analytic solution is achieved, and then a simple GFM control is proposed to make the WPG actively supporting the grid synchronization. • Reduced-order dynamic model of the PHES-based WPG is derived, and available kinetic and hydraulic energy storage can be easily analyzed to perform inertia and primary frequency responses. • A comprehensive transients-dynamics simulation framework of the PHES-WPG is implemented to perform diverse studies including grid faults, scheduled commands, and variant wind speed profiles.
No takes yet. Share an insight, caveat, or question.
Ye et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: