Key result
Transcatheter aortic valve implantation was associated with a significant elevation in plasma neurofilament light chain levels, with a mean increase of 18 pg/mL compared to baseline.
Why the study?
TAVI is linked to a high incidence of silent brain infarcts, but whether plasma neurofilament light chain, a marker of neuronal injury, is elevated after TAVI was unknown.
Does transcatheter aortic valve implantation increase plasma neurofilament light chain levels in patients undergoing the procedure?
Observational (n=31)
No
Does transcatheter aortic valve implantation increase plasma neurofilament light chain levels in patients undergoing the procedure?
Plasma neurofilament light chain levels are significantly elevated after TAVI, suggesting potential subclinical neuronal injury that warrants further investigation.
Answers are grounded in this paper and cite their sources.
TAVI-associated plasma NFL rise may indicate subclinical neuronal injury; hypothesis-generating and leaves open need for prospective outcome studies.
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is associated with a high incidence of new silent brain infarcts (SBIs) on postprocedural neuroimaging. A venous blood sample reflecting neuronal damage following TAVI could help identify patients with potential SBIs. We aimed to investigate if a biochemical marker of neuronal injury, neurofilament light chain (NFL), is elevated after TAVI. METHODS: In this observational study, NFL was measured in plasma from 31 patients before and after TAVI. Multivariable regression analysis was performed to investigate any effect of clinical- and procedure-related factors on differences in NFL levels before and after TAVI. RESULTS: Samples were collected 41 (14-81) days before and 44 (35-59) days after TAVI, median (interquartile range). Median age was 81 (77-84) years, and 35% were female. No patient had any overt procedure-related neurological complications. The geometric mean (95% confidence interval) of the NFL concentration was 30 (25-36) pg/mL before TAVI and 48 (39-61) pg/mL, after TAVI, p <0.001. None of the included variables in the multiple linear regression model were statistically significantly associated with the difference in levels before and after TAVI. CONCLUSIONS: NFL levels in plasma were higher after TAVI as compared with levels before, with a mean increase of 60% (18 pg/mL). Further studies including neuroimaging and cognitive outcomes are needed to understand the potential value of measuring NFL in relation to TAVI.
No takes yet. Share an insight, caveat, or question.
Sjölin et al. (2023) conducted an observational in Severe aortic stenosis (n=31). Transcatheter aortic valve implantation (TAVI) vs. Baseline (before TAVI) was evaluated on Plasma neurofilament light chain (NFL) concentration (MD 18 pg/mL, p=<0.001). Transcatheter aortic valve implantation was associated with a significant elevation in plasma neurofilament light chain levels, with a mean increase of 18 pg/mL compared to baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: