Key result
The exclusive use of a novel 25-mm circular mapping catheter for cryoballoon ablation of atrial fibrillation resulted in a real-time pulmonary vein recording rate of 80% and acute isolation of 98% of targeted veins.
Observational (n=40)
No
The use of a novel 25-mm circular mapping catheter during cryoballoon ablation for atrial fibrillation is safe and provides a high rate (80%) of real-time pulmonary vein recordings to guide therapy.
Answers are grounded in this paper and cite their sources.
Supports feasibility of exclusive novel catheter use for real-time PV recording; hypothesis-generating pending randomized outcome data.
BACKGROUND: Real-time recording of pulmonary vein isolation (PVI) using a circular mapping catheter has become a key aspect of cryoballoon (CB) ablation. The aim of this study was to investigate the procedural safety, efficacy and rate of real-time pulmonary vein (PV) recording using a novel circular mapping catheter with a 25-mm loop size for CB-based PVI. METHODS AND RESULTS: A total of 40 patients with symptomatic atrial fibrillation (AF) underwent PVI using a second-generation CB and a novel 25-mm circular mapping catheter. A total of 159 PV were identified and successfully isolated. Real-time PV recording was achieved in 80% of the PV. In 3 right inferior PV the circular mapping catheter had to be exchanged for a stiff guidewire due to insufficient mechanical support. Therefore, acute PVI using exclusively the circular mapping catheter was achieved in 156/159 PV (98%). Mean procedure and fluoroscopy times were 66±21 min and 15±6 min, respectively. Transient phrenic nerve palsy occurred in 1 patient as the only procedural complication. CONCLUSIONS: The exclusive use of a novel 25-mm circular mapping catheter for CB ablation of AF results in a real-time PV recording rate of 80% and isolation of 98% of targeted PV.
No takes yet. Share an insight, caveat, or question.
Reißmann et al. (2017) conducted an observational in Symptomatic paroxysmal or persistent atrial fibrillation (n=40). 25-mm circular mapping catheter (Achieve Advanced) was evaluated on Rate of real-time recordings of cryoballoon-based pulmonary vein isolation (95% CI 73-86). The exclusive use of a novel 25-mm circular mapping catheter for cryoballoon ablation of atrial fibrillation resulted in a real-time pulmonary vein recording rate of 80% and acute isolation of 98% of targeted veins.
Synapse has enriched 10 related papers. Consider them for comparative context: