Key result
Luminal esophageal temperature monitoring using a deflectable probe and intracardiac echocardiography resulted in no esophageal thermal injury (0%) among 45 patients undergoing AF ablation.
Why the study?
Does luminal esophageal temperature monitoring with a deflectable probe and intracardiac echocardiography prevent esophageal injury in patients undergoing atrial fibrillation ablation?
Observational (n=45)
Does luminal esophageal temperature monitoring with a deflectable probe and intracardiac echocardiography prevent esophageal injury in patients undergoing atrial fibrillation ablation?
A strategy of optimal LET probe placement using a deflectable probe and intracardiac echocardiography guidance, combined with cessation of ablation with a 2°C rise in LET, may prevent esophageal thermal injury during AF ablation.
May prevent esophageal injury in AF ablation; hypothesis-generating and requires randomized confirmation before practice change.
BACKGROUND: Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. METHODS AND RESULTS: Forty-five consecutive patients undergoing an atrial fibrillation ablation procedure followed by esophageal endoscopy were included in this prospective observational pilot study. LET monitoring was performed with a 7F deflectable ablation catheter that was positioned as close as possible to the site of left atrial ablation using the deflectable component of the catheter guided by visualization of its position on intracardiac echocardiography. Ablation in the posterior left atrial was limited to 25 W and terminated when the LET increased 2°C from baseline. Endoscopy was performed 1 to 2 days after the procedure. All patients had at least 1 LET elevation >2°C necessitating cessation of ablation. Deflection of the LET probe was needed to accurately measure LET in 5% of patients when ablating near the left pulmonary veins, whereas deflection of the LET probe was necessary in 88% of patients when ablating near the right pulmonary veins. The average maximum increase in LET was 2.5±1.5°C. No patients had esophageal thermal injury on follow-up endoscopy. CONCLUSIONS: A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.
No takes yet. Share an insight, caveat, or question.
Leite et al. (2011) conducted an observational in Atrial fibrillation (n=45). Luminal esophageal temperature monitoring with a deflectable probe and intracardiac echocardiography was evaluated on Esophageal thermal injury on follow-up endoscopy. Luminal esophageal temperature monitoring using a deflectable probe and intracardiac echocardiography resulted in no esophageal thermal injury (0%) among 45 patients undergoing AF ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: