December 1, 1995Hypertension

A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring

View Full Paper
Ask AI
Bookmark
Share

Design

Guideline

Authors

Jan A. Staessen
Jan A. StaessenGeneral / Preventive / Lipids
RFRobert FagardPreventive CardiologyLTLutgarde ThijsUniversity College Dublin

Discussion

Loading...

Member takes

Overview

Clinicians must confirm ABPM validation in pregnancy and elderly before use; extends standards by requiring manufacturer algorithm disclosure.

Key Points

  • The review aims to examine the technical details and validity of ambulatory blood pressure monitoring methods.
  • Based on the Fourth International Consensus Conference on Ambulatory Blood Pressure Monitoring held in Leuven, Belgium, in 1994.
  • Assessment of technical aspects, limitations, and validation requirements of various monitoring devices.
  • Analysis of different techniques, like auscultatory and oscillometric, with emphasis on their specific advantages.
  • Advocates for the disclosure of algorithms by manufacturers for device transparency.
  • Highlights the volume-clamp method as a promising technique for continuous monitoring in diverse settings.
  • Emphasizes the need for accuracy validation in specific populations such as the elderly or pregnant women.

Structured PICO

I
Intervention
Ambulatory blood pressure monitoring (ABPM)

This consensus document provides foundational recommendations on the technical aspects and validation requirements for ambulatory blood pressure monitoring devices.

Cite This Study

Staessen et al. (1995) studied this question.

synapsesocial.com/papers/6a20dcf134bef10fdaeb1440https://doi.org/10.1161/01.hyp.26.6.912
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Basedon the Cuff-Oscillometric Method and the Korotkoff Sound Technique1992 · 134 citations
  2. 2Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.1983 · 239 citations
  3. 3Discrepancies in Recording Systolic Blood Pressure of Elderly Persons by Ambulatory Blood Pressure Monitor1992 · 19 citations
  4. 4Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.1993 · 259 citations
  5. 5Accuracy of auscultatory blood pressure measurement with a long cuff.1987 · 53 citations