Key result
Inhaled nitric oxide significantly altered the distribution of pulmonary blood flow in healthy subjects, increasing Global Fluctuation Dispersion by 5.4 percentage points during hypoxia.
Why the study?
Does inhaled nitric oxide alter the distribution of pulmonary blood flow in healthy human lungs under varying oxygen fractions?
Does inhaled nitric oxide alter the distribution of pulmonary blood flow in healthy human lungs under varying oxygen fractions?
Inhaled nitric oxide alters pulmonary blood flow distribution in both hypoxic and normoxic healthy subjects, suggesting baseline hypoxic pulmonary vasoconstriction exists even in normoxia.
No immediate clinical implications in healthy subjects; leaves open nitric oxide effects on pulmonary blood flow in disease.
Hypoxic pulmonary vasoconstriction (HPV) is thought to actively regulate ventilation-perfusion (V̇a/Q̇) matching, reducing perfusion in regions of alveolar hypoxia. We assessed the extent of HPV in the healthy human lung using inhaled nitric oxide (iNO) under inspired oxygen fractions (FiO2 ) of 0.125, 0.21, and 0.30 (a hyperoxic stimulus designed to abolish HPV without the development of atelectasis). Dynamic measures of blood flow were made in a single sagittal slice of the right lung of five healthy male subjects using an arterial spin labeling (ASL) MRI sequence, following a block stimulus pattern (3 × 60 breaths) with 40 ppm iNO administered in the central block. The overall spatial heterogeneity, spatiotemporal variability, and regional pattern of pulmonary blood flow was quantified as a function of condition (FiO2 × iNO state). While spatial heterogeneity did not change significantly with iNO administration or FiO2 , there were statistically significant increases in Global Fluctuation Dispersion, (a marker of spatiotemporal flow variability) when iNO was administered during hypoxia (5.4 percentage point increase, P = 0.003). iNO had an effect on regional blood flow that was FiO2 dependent (P = 0.02), with regional changes in the pattern of blood flow occurring in hypoxia (P = 0.007) and normoxia (P = 0.008) tending to increase flow to dependent lung at the expense of nondependent lung. These findings indicate that inhaled nitric oxide significantly alters the distribution of blood flow in both hypoxic and normoxic healthy subjects, and suggests that some baseline HPV may indeed be present in the normoxic lung.
No takes yet. Share an insight, caveat, or question.
Asadi et al. (2014) studied Healthy human lung (n=5). Inhaled nitric oxide vs. Baseline (no inhaled nitric oxide) was evaluated on Global Fluctuation Dispersion (FD Global) during hypoxia (5.4 percentage point increase, p=0.003). Inhaled nitric oxide significantly altered the distribution of pulmonary blood flow in healthy subjects, increasing Global Fluctuation Dispersion by 5.4 percentage points during hypoxia.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: