Key result
Quantification of left ventricular shape differentiated pediatric pulmonary hypertension subjects from matched controls with a receiver operator curve accuracy index of 0.85.
Why the study?
Does quantification of left ventricular shape using Fourier decomposition of echocardiographic images differentiate pediatric patients with pulmonary hypertension from healthy controls?
Case-Control (n=106)
Does quantification of left ventricular shape using Fourier decomposition of echocardiographic images differentiate pediatric patients with pulmonary hypertension from healthy controls?
Effect estimate: Accuracy index 0.85
p-value: p=< 0.05
Quantification of left ventricular shape using Fourier decomposition of echocardiographic images accurately differentiates pediatric patients with pulmonary hypertension from healthy controls.
LV shape quantification may support echocardiographic detection of pediatric pulmonary hypertension; leaves open prospective validation before clinical adoption.
Changes in left ventricle (LV) shape are observed in patients with pulmonary hypertension (PH). Quantification of ventricular shape could serve as a tool to noninvasively monitor pediatric patients with PH. Decomposing the shape of a ventricle into a series of components and magnitudes will facilitate differentiation of healthy and PH subjects. Parasternal short-axis echo images acquired from 53 pediatric subjects with PH and 53 age and sex-matched normal control subjects underwent speckle tracking using Velocity Vector Imaging (Siemens) to produce a series of x,y coordinates tracing the LV endocardium in each frame. Coordinates were converted to polar format after which the Fourier transform was used to derive shape component magnitudes in each frame. Magnitudes of the first 11 components were normalized to heart size (magnitude/LV length as measured on apical view) and analyzed across a single cardiac cycle. Logistic regression was used to test predictive power of the method. Fourier decomposition produced a series of shape components from short-axis echo views of the LV. Mean values for all 11 components analyzed were significantly different between groups (p < 0.05). The accuracy index of the receiver operator curve was 0.85. Quantification of LV shape can differentiate normal pediatric subjects from those with PH. Shape analysis is a promising method to precisely describe shape changes observed in PH. Differences between groups speak to intraventricular coupling that occurs in right ventricular (RV) overload. Further analysis investigating the correlation of shape to clinical parameters is underway.
No takes yet. Share an insight, caveat, or question.
Wagner et al. (2017) conducted a case-control in Pulmonary hypertension (n=106). Quantification of left ventricular shape vs. Normal controls was evaluated on Differentiation of healthy and PH subjects using LV shape quantification (Accuracy index 0.85, p=< 0.05). Quantification of left ventricular shape differentiated pediatric pulmonary hypertension subjects from matched controls with a receiver operator curve accuracy index of 0.85.