May 10, 2007Clinical Chemistry84 citationsOpen Access

Comparison of Brain Natriuretic Peptide (BNP) and Amino-Terminal ProBNP for Early Diagnosis of Heart Failure

View Full Paper
MEMichele EmdinCPClaudio PassinoCPConcetta Prontera

Key Result

NT-proBNP was more accurate than BNP in differentiating stage C heart failure from stages A and B patients and healthy controls (P<0.001).

Study Design

Type

Cohort (n=1,002)

Structured PICO

Does NT-proBNP improve diagnostic accuracy compared to BNP for the early diagnosis of preclinical and mild heart failure?

P
Population
1,002 participants, comprising 182 healthy controls and a prospective cohort of 820 heart failure patients across AHA/ACC stages A to D.
E
Exposure
Amino-terminal proBNP (NT-proBNP) plasma assay
C
Comparator
Brain natriuretic peptide (BNP) plasma assay
O
Outcome
Diagnostic accuracy for preclinical and mild heart failure (differentiating AHA/ACC HF stages)surrogate

NT-proBNP demonstrates superior diagnostic accuracy compared to BNP for identifying mild and preclinical heart failure across AHA/ACC stages.

Main Result

p-value: p=<0.001

Abstract

BACKGROUND: We compared the diagnostic accuracy of brain natriuretic peptide (BNP) and amino-terminal proBNP (NT-proBNP) for diagnosis of preclinical and mild heart failure (HF). METHODS: We assayed plasma NT-proBNP and BNP in 182 healthy controls and in a prospective cohort of 820 HF patients divided according to the American Heart Association/American College of Cardiology classification. These included 86 patients in stage A mean (SE) ejection fraction 61% (1%); mean (SE) age 47 (2) years, 255 in stage B 65% (2%); 62 (1) years, 420 patients in stage C 35% (1%); 68 (1) years and 59 in stage D 25% (1%); 74 (1) years. Diagnostic accuracies of BNP and NT-proBNP were evaluated by ROC analysis, and a multivariate linear regression model was applied to predict HF staging. RESULTS: Median BNP and NT-proBNP concentrations increased from stage A to D 57-fold and 107-fold, respectively. Both assays were accurate (P <0.001) in separating stage B from controls or stage A, and stage C from controls or stage A or B. NT-proBNP was more accurate (P <0.001) than BNP in differentiating stage C from stages A and B patients and controls and was a better predictor of HF classification in a model including age, sex, and renal function (P <0.001). CONCLUSIONS: Monitoring BNP or NT-proBNP enabled identification of asymptomatic patients at risk for the development of HF. NT-proBNP showed better accuracy than BNP for identifying mild HF.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Emdin et al. (2007) conducted a cohort in Heart failure (n=1,002). NT-proBNP vs. BNP was evaluated on Diagnostic accuracy for differentiating heart failure stages (p=<0.001). NT-proBNP was more accurate than BNP in differentiating stage C heart failure from stages A and B patients and healthy controls (P<0.001).